Community CU-LR030408Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF IN-PLACE DENSITY TESTS
CLIENT: Community Credit Union DATE: 8 April 2003
PROJECT: Community Credit Union-Coppell Branch JOB NO.: 02.1058
687 Denton Tap Rd., Coppell, TX
MATEP.IAL DESCRIPTION: 1) Flex Base -Crushed Stone
ASTM D 698 STANDARD PROCTOR: 1) 108.0 pcf @ 16.0% Moisture
LOCATION PROCTOR
Southeast Aooroach
44) approx. 15' north of south curbline 1
approx. 5' east of existing paving
45) approx. 7' north of south curbline 1
approx. 15' west of Denton Tap Rd.
46) approx. 15' south of north curbline 1
approx. 3' west of Denton Tap Rd.
MOISTURE DRY PERCENT REQUIRED
LIFT CONTENT DENSITY COMPACTION COMPACTION
PCF % %
Flex Base 14.3 118.9 110.1 95+*
Flex Base 13.4 113.3 104.9
Flex Base 15.5 107.3 99.4
*Specification furnished by contractor.
TECHNICIAN: CDJ
DISTRIBUTION: (1) Community Credit Union
(1) PGAL, Inc.
41) Nelson Consulting, Inc.
111 Mycon General Contractors
12) City of Coppell
~"`
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148