Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Callahan-LR030625
FAR.CO CONSVLTANTB, INC. 11440 Reeder Rd. • Dallas, TX 75229 Tel. (214) 352-4100 • Fax (214) 352-4811 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Connell. Texas CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Sample Date: 06-25-03 Project No.: M02-412 C3 Constructors 111595 CONCRETE SUPPLIER: Redi-Mix 86 PLANTITRUCK: 1/ 136 90 MIX ID NUMBER: 655 10:58 a.m. AIR (%} (ASrnn c-173> 3.5 11:52 a.m. WATER ADDED (gal): 5 Partly cloudy SLUMP (inches) (ASrM c-~a3) 5 Floor slab topping -wes t balcony CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard ti" x 12", 28.27 square irtches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) 1 A 7 7-2-03 80500 2850 3000/ 28 da s 1 B 28 7-23-03 122000 4320 1 C 28 7-23-03 118500 4190 1 D Hold - Specificafions: Making 8 ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curin Remarks: Unit weight = 121.8 pcf. Mir contained fiber mesh. Technician: Gary Moore, CET FARGO CONSULTANTS, INC. Checked By: k'~-= Distribution: Bonner Associates -Tim Bonner Ciry of Coppell -Rick Odell C3 Constructors -Taylor Barnes Environments/ Services ^ Geotechnica/ Engineering ~ Construction Materia/s Testing FAROO CONBUI.TANTB, INC. C3 Constructors COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Connell. Texas CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONGRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: 11440 Reeder Rd. • Dallas, TX 75229 Tel. (214) 352-4100 • Fax (214) 352-4811 Sample Date: 06-25-03 Project No.: M02-412 111595 CONCRETE SUPPLIER: Redi-Mix 86 PLANTITRUCK: 1/ 136 90 MIX ID NUMBER: 655 10:58 a.m. AIR (%) (ASTM c-173) 3.5 11:52 a.m. WATER ADDED (gal): 5 Partly cloudy SLUMP (inches) (ASTM c-143) 5 Floor slab topping -west balcony CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12",28.27 square`inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH (Psi) SPECIFIED COMPRESSIVE STRENGTH (Psi} 1A 7 7-2-03 80500 2850 3000128 da s 1 B 28 7-23-03 1 C 28 7-23-03 1 D Hold - Specifications: Making & ASTM C-39 Testing Methods: ASTM C-143, ASTM C-39 Curin rcemarxs.• unu wetgnt = 1 L/.tf pcj. Mix contained fiber mesh. Technician: Gary Moore, CET FARGO CONSULTANTS, INC. Checked By: Distribution: Bonner Associates -Tim Bonner City of Coppell -Rick Odell C3 Constructors -Taylor Barnes Enuironmenta/ Services ~ GeotecbnicaJ Engineering ~ Construction Maferia/s Testing