Loading...
Callahan-LR03050911440 Reeder Rd. • Dallas, TX 75229 Faxoo coxauranxrs, rxc. Tel. (214) 352-4100 • Fax (214) 352-4811 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Connell. Texas Sample Date: OS-09-03 Project No.: M02-412 ~ CONCRETE INFORMATION ~ CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: C3 Constructors 109367 CONCRETE SUPPLIER: Redi-Mix 78 PLANT/TRUCK: 1 / 234 85 MIX ID NUMBER: 916MR 11:55 p.m. AIR (%) (ASTM C-173) 1.5 12:30 p.m. WATER ADDED (gal): 0 Cloudy SLUMP (inches) (ASTM c-~a3) 2'h Sidewalk -north of drive approach entrance parallel to Denton Tap Road (Drive approach to 20' north of drive approach) CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) 1A 7 5-16-03 86000 3040 3000/28da s 1 B 28 6-06-03 1 C 28 6-06-03 1 D Hold - Specifications: Making & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curin Remarks: A representative for C3 Constructors was informed of entrained air test result. Technician: Moe Munim, EIT Distribution: Bonner Associates -Tim Bonner City of Coppell -Rick Odell C3 Constructors -Taylor Barnes FARGO CONSULTANTS, INC. Checked By: ~/~~ Consu/ting ~ Geotechnical Engineering ^ Constroction Materia/s Testing ] 1440 Reeder Rd. • Dallas, TX 95229 anxao coxaurraxrs, rrrc. Tel. (214) 352-4100 • Fax (214) 352-4811 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates Sample Date: OS-09-03 PROJECT: Callahan Addition Project No.: M02-412 Co ell, Texas CONCRETE INFORMATION- CONTRACTOR: C3 Constructors TICKET NO.: 109367 CONCRETE SUPPLIER: Redi-Mix AMBIENT TEMP. (°F): 78 PLANTITRUCK: 1/ 234 CONCRETE TEMP. (°F): 85 MIX ID NUMBER: 916MR TIME BATCHED: 11:55 a.m. AIR (%) (ASTM C-173) 1.5 TIME SAMPLED: 12:30 p.m. WATER ADDED (gal): 0 WEATHER CONDITION: Cloudy SLUMP (inches) (ASTM C-143) 2 LOCATION OF PLACEMENT: Sidewalk -north of drive approach entrance parallel to Denton Tap Road (Drive approach to 20' north of drive approach) CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 2837 square inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH (PSI) SPECIFIED COMPRESSIVE STRENGTH IPSI) 1A 7 5-16-03 86000 3040 3000/ 28 da s 16 28 6-06-03 115000 4070 1C 28 6-06-03 112500 3980 1 D Hold - Specifications: Making & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curin Remarks: A representative for C3 Constructors was informed of entrained air test result. Technician: Moe Mluum, EIT FARGO CONSULTANTS, INC. Distribution: Bonner Associates -Tim Bonner City of Coppell -Rick Odell C3 Constructors - Taylor Bames Checked By: GGIL Consulting / Geotechnica/ Engineering ^ Construction Materia/s Testing