Callahan-LR030414
FAItOO OONBULTANT9, INO. 11440 Aeeder Rd. • Dallas, TX 7522_9 Tel. (214) 352-4100 • Fax (214) 352-481 I COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Coppell, Texas Sample Date: 04-14-03 Project No.: M02-412 CONCRETE INFORMATION I CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT C3 Constructors 107579 CONCRETE SUPPLIER: Redi-Mix 70 PLANT/TRUCK: 1/ 234 73 MIX ID NUMBER: 916 12:00 p.m. AIR (%) (ASTM C-173) 3.8 12:30 p.m. WATER ADDED (gat): 15 Clear SLUMP (Inches) (ASTM c-1431 7 Sidewalk - 10' north by 30' east from southeast corner of building CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH lPsl) SPECIFIED COMPRESSIVE STRENGTH (Psll 1A 7 4-21-03 50000 1770 3000/ 28 da s 1B 28 5-12-03 1C 28 5-12-03 1 D Hold - SpeciflgGons: Making 8 ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curin ; 2emarks: Informed superintendent ofslump test result. Technician: Jeff Clifton Distribution: Bonner Associates -Tim Bonner City of Coppell -hick Odell C3 Constructors -Taylor Barnes FARGO CONSULTANTS, INC. Checked By: GfRL Consu/ting ~ Geotechnical Engineering /Construction Matena/s Testing FA&00 CONBULTANTB, INC. 11440 Reeder Rd. • Dallas, TX 75229 Tel. (214) 352-4100 • Fax (214) 352-4811 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Connell, Texas Sample Date: 04-14-03 Project No.: M02-412 ~ CONCRETE INFORMATION ~ CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: C3 Constructors 107579 CONCRETE SUPPLIER: Redi-Mix 70 PLANTITRUCK: 1/ 234 73 MIX ID NUMBER: 916 12:00 p.m. AIR (%) (ASTM C-173) 3.8 12:30 p.m. WATER ADDED (gal): 15 Clear SLUMP (inches) (ASTM c-t43) 7 Sidewalk - 10' north by 30' east from southeast corner of building CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard `6" x 12", 28.27 square.-Inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH lpsi) SPECIFIED COMPRESSIVE STRENGTH (Psl) 1 A 7 4-21-03 50000 1770 3000! 28 da s 1 B 28 5-12-03 90000 3180 1 C 28 5-12-03 85000 3010 1 D Hold - Specifications: Making & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curin Remarks: Informed superintendent of slump test result. Technician: Jeff Clifton FARGO CONSULTANTS, INC. Checked By: -~~ Distribution: Bonner Associates -Tim Bonner City of Coppell -Rick Odell C3 Constructors -Taylor Barnes Consu/ting i Geotechnica/Engineering ^ Construction Materials Testing