Loading...
Callahan-LR030117i FA8.00 CONBULTANTB, INC. 11440 Reeder Rd. • Dallas, TX 75229 Tel. (214) 352-4100 • Fax (214) 352-4811 REPORT OF FIELD COMPACTION Tested For: Bonner Associates Project: Callahan Addition Coppell, Texas Date Performed: 01-17-03 FCI Project No.: M02-412 Density: Per ASTM D-2922 Moisture: Per ASTM D-3017 Test Mode (DT / BS): DT MOISTURE/DENSITY RELATIONS Gauge Manuf: Humboldt Gauge Model: HS-SOOlEZ Probe Depth: 8 inches Proctor No• Material Description Optimum Moisture % Maximum Dry Densit PCF 5 Reddish Brown Clayey Sand (Select Fill) 12.0 121,5 7 Crushed Concrete 14.0 119.0 IN-PLACE TEST RESULTS Test NO Elevation Location Proctor Percent Dry D y Yercen[ ' Lfft Nu, Moisture (PCF Density 92 FG-1' Sanitary sewer line - 35' north by 5' west from 5 13 8 116 8 96 1 southeast comer of building pad . . . 93 FG-0.5' Sanitary sewer line - 10' south by 5' west from 5 13 6 115 4 95 0 northeast corner of building pad . . . 94F FG Drive approach, 15' east from east edge of Denton Tap Road by 7' south from center line of fire lane 7 16.9 101.8 85.5 95F FG Drive approach, 9' east from east edge of Denton Tap Road by 15' north from center line of fire lane 7 16.1 105.0 88.2 96 FG-1.5' Sanitary sewer line - 20' north from south building line 5 11 3 119 1 98 0 at center of building ad . . . 97 FG Sanitary sewer line - 40' south by 5' west from northeast corner of building pad 5 14.0 118.5 97.5 98 FG-1' Sanitary sewer line - 35' north from south building line 5 13 3 115 8 95 3 at center of buildin ad . . . 99 FG-0.5' Sanitary sewer line - 35' south from north building line 5 14 0 116 3 95 7 at center of building ad . . . 100 FG Sanitary sewer line -10' south by 15' west from 5 13 0 115 9 95 4 northeast corner of building pad . . . (K) AFTER'PEST NUMBER INllICATES RETEST (F) INDICATES FAILURE TO COMPLY WITH PROJECT REQUIREMEN'CS Technician: Jeff Clifton Checked By: Distribution: Bonner Associates -Tim Bonner City of Coppell -Rick Odell C3 Constructors -Taylor Barnes LIMITATIONS: The test results presented herein wa'e prepared based upon the specific samples provided for testing. We azsume no responsibility fa~ variation in quality (composition, appeazance, performance, etc.) or any other failure of similar subject matter provided by persons or conditions over which we have no control. Our ieners and repotts are for the exclusive use of [he clienCs to whom they are addressed and shall not be reproduced except in full without the written approval of Fargo Consultants, Inc. Environments/ Services ^ Geotechnica/ Engineering ~ Construction Materia/s Testing