Loading...
Callahan-LR030108i FAROO CONBULTANTB, INC. 11440 Reeder Rd. • Dallas, TX 75229 Tel. (214) 352-4100 • Fax (214) 352-4811 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Connell. Texas Sample Date: 01-08-03 Project No.: M02-412 CONCRETE INFORMATION CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Guzman Construction 3154459 CONCRETE SUPPLIER: LMC 69 PLANTffRUCK: 31964 68 MIX ID NUMBER: 842 1:24 p.m. AIR (%) (ASTM C-231) - 2:10 p.m. WATER ADDED (gal): 0 Clear SLUMP (inches) (ASTM c-143- 4'/4 Storm drain inlets, northwest corner of east parking and south o f southeast corner of building pad for south fire lane. CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 2827 square inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH (Psi) SPECIFIED COMPRESSIVE STRENGTH (Psi) 1A 7 1-15-03 92000 3250 3000/ 28 da s 1 B 28 2-05-03 120000, 4240 1C 28 2-05-03 115000 4070 1 D Hold - Specifications: Making & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curin Technician: Jeff Clifton Distribution: Bonner Associates -Tim Bonner City of Coppell -Rick Odell C3 Contractors -Taylor Barnes FARGO CONSULTANTS, INC. Checked By: ~/ rl~(i Environmental Services ^ Geofechnical Engineering ~ Construction Materials Testing FAROO CONeULTANTB, INC. 11440 Reeder Rd. • Dallas, TX 75229 Tel. (214) 352-4100 • Fax (214) 352-4811 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Connell. Texas Sample Date: 01-08-03 Project No.: M02-412 ~ CONCRETE INFORMATION CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Guzman Construction 3154459 CONCRETE SUPPLIER: LMC 6g PLANTITRUCK: 3/ 964 68 MIX ID NUMBER: 842 1:24 p.m. AIR (%) (asrM c-zit) - 2:10 p.m. WATER ADDED (gal): 0 Clear SLUMP (inches) (asTM C-tai) 4'/< Storm drain inlets, northwest corner of east parking and south of southeast corner of building pad for south fire lane. CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 8" x 72", 28.27 square inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH (Psi) SPECIFIED COMPRESSIVE STRENGTH (Psi) 1A 7 1-15-03 92000 3250 3000/28da s 1 B 28 2-05-03 1 C 28 2-05-03 1 D Hold - Specifications: Making 8 ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curing: Technician: Jeff Clifton Distribution: Bonner Associates -Tim Bonner City of Coppell -Rick Odell C3 Contractors -Taylor Barnes FARGO CONSULTANTS, INC. Checked By: Environments/ Services ^ Geolechnica/ Engineering /Construction Materia/s Testing FAR.00 CONSVLTANTB, INC. REPORT OF FIELD COMPACTION 11440 Reeder Rd. • Dallas, TX 75229 Tel. (214) 352-4100 • Fax (214) 352-4811 Tested For: Bonner Associates Date Performed: 01-08-03 Project: Callahan Addition FCI Project No.: M02-412 Coppell, Texas Density: Per ASTM D-2922 Gauge Manuf.: Humboldt Moisture: Per ASTM D-3017 Gauge Model HS-5001 EZ Test Mode (DT / BS): DT Probe Depth: 8 inches MOISTURE/DEN5ITY RELATIONS Proctor No. Material Description Optimum Moisture % Maximum Dry Densi PCF 4 Dark Brown Clay and Brown Clay with Calcareous nodules 22.0 101.5 IN-PLACE TEST RESULTS Test No Elevation °r Location Proctor Percent Dry Density Percent . Lift No. Moisture PCF Densit y 64 1st Water line, 25' east from vault box at the southwest portion of project site 4 22.3 100.8 99.3 "d Water line, 30' east from vault box at the southwest 65 2 ortion of roject site 4 22.4 101.5 100 66 3`d Water line, 40' east from vault box at the southwest portion of roject site 4 23.1 100.5 99.0 67 4tn Water line, 45' east from vault box at the southwest portion of project site 4 23.6 101.2 99.7 (R)AFTER TEST NUMBER INDICATES RETEST (F) INDICATES FAILURE TO COMPLY WITH PROJECT REQUIREMENTS Technician: Jeff Clifton Checked By ~! Distribution: Bonner Associates -Tim Bonner City of Coppell -Rick Odel] C3 Contractors -Taylor Barnes LIMITATIONS'. The test results presented herein were prepared based upon the specific satrWles provided for testing. We assume no responsibility for variation in quality (conWosi[ion, appearance, performance, etc.) or any other failure of similar subject matter provided by persons or conditions over which we have no control. Uur letters and reports are for the exclusive use of the clienPs to whom they are addressed and shall not be reproduced except in full without the written approval of Fat'go Consultants, Inc. Environments/ Services ~ Geolechnica/ Engineering ^ Construction Materials Testing