Loading...
Callahan-LR021119~FARCO CONSULTANTS, INC. 11440 Reeder Rd. • Dallas, TX 75225 Tel. (214) 352-4100 • Fax (214) 352-481 I COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Coppell, Texas Sample Date: 11-19-02 Project No.: M02-412 ~ CONCRETE INFORMATION 1 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT Guzman Construction 6186076 70 75 1:40 p.m. 2:59 p.m. Clear Sanitary sewer manhole CONCRETE SUPPLIER: LMC PLANT/TRUCK: 6/ 804 MIX ID NUMBER: 842 AIR (%} (ASTM C-231) - WATER ADDED (gal): 10 SLUMP (Inch@S} (ASTM C-143) 2 Y< CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH (Psi) SPECIFIED COMPRESSIVE STRENGTH (Psi) 1A 7 11-26-02 124500 4400 4000128 da s 1B 28 12-17-02 153500 5430 1 C 28 12-17-02 144500 5110 1 D Hold - Specifications: Making & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curin Cylinders made by: Dan Rotty, EIT FARGO CONSULTANTS, INC. Distribution: Bonner Associates -Paul Pitts City ofCoppell -Rick Odell C3 Contractors -Taylor Barnes Checked $y: /"/vvrc Enviionmenta/ Services / Geotechnical Engineering ~ Construction Materia/s Testing /r/ - FAROO CONSULTANTS, INC. 11-19-02 Airport Pit (Per contractor) Stockpile On-Site (Haul-In) Tan Sandy Clay REPORT OF ATTERBERC LIMITS TEST (ASTM D4318) Tested For: Bonner Associates Project Name: Callahan Addition Coppell, Texas Sample Date: Source: Sample Location: Material Description 11440 Reedcr Rd. • Dalin,, T~ 7;??9 Tel. (214) 352-4100 • Fa.r (21~~ i52.4R11 Date Performed: 11-19-02 FCI Project No.: M02-412 Test Results Liquid Limit 42 Plastic Limit 23 Plasticity Index 19 RE~1ARKS: Material does trot meet project reguiretnents for Select Fill. Technician: Dan Rotty, E[T Distribution: Botmer Associates -Pau] Pitts City ofCoppell -Rick Odell C3 Contractors -Taylor Barnes Respectfully Submitted, Fargo Consultants, Inc. Checked by: _ j< c _ Consulting ~ Geotechnica/ Engineering ^ Construction Materials resting FAROO CONSULTANTS, INC. 11440 Reeder Rd. • Dallas, TX 75229 Tel. (214) 352-4100 • Fax (214) 352-4811 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Bonner Associates PROJECT: Callahan Addition Coppell, Texas Sample Date: 11-19-02 Project No.: M02-412 I CONCRETE INFORMATION CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Guzman Construction 6186076 70 75 1:40 p.m. 2:59 p.m. Clear Sanitary sewer manhole CONCRETE SUPPLIER: LMC PLANT/TRUCK: 6/ 804 MIX ID NUMBER: 842 AIR (%) (ASTM C-231) - WATER ADDED (gal): 10 SLUMP (Inches) (ASTM C-143) 2'/n CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (Pounds) COMPRESSIVE STRENGTH (Psi) SPECIFIED COMPRESSIVE STRENGTH (Psi) 1A 7 11-26-02 124500 4400 4000/ 28 da s 1 B 28 12-17-02 1 C 28 12-17-02 1 D Hold - Specifica[ions: Malting & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curin Cylinders made by: Dan Rotty, EIT FARGO CONSULTANTS, INC. Distribution: Boomer Associates -Paul Pitts City of Coppell -Rick Odell C3 Contractors -Taylor Barnes Checked By: - Consulting ~ Geotechnica/Engineering ^ Construction Materia/s Testing