Callahan-LR021112FAROO CONBULTANTB, INC. 11440 Reeder Rd. • Dallas, TX 75229 (214) 352-4100 • Fax (214) 352-4811 REPORT OF FIELD COMPACTION Tested For: Bonner Associates Date Performed: 11-12-02 Project: Callahan Addition FCI Project No.: M02-412 Coppell, Texas Density: Per ASTM D-2922 Gauge Manuf.: Humboldt Moisture: Per ASTM D-3017 Gauge Model: HS-SOOlEZ Test Mode (DT / BS):DT Probe Depth: 6 inches MOISTURE/DENSITY RELATIONS Proctor No. Material Description Optimum Moisture % Maximum Dry Densit PCF 4 Dark Brown Clay and Brown Clay with Calcareous nodules 22.0 101.5 IN-PLACE TEST RESULTS Test No Elevation or Location Proctor Percent Dry Density Percent Lift No. Moisture PCF Densit y `I' Building pad, 30' south by 20' east from northwest 29 14 corner of ad 4 27.6 92.8 91.4 30 14`h Building pad, 20' north by 30' west from southeast corner of ad 4 27.9 93.8 92.4 I<) nr I r_rc I r~ I rvungts tlc wuICA I ES IcErEST (F) 1NUICATES FAILURE TO COMPLY WITH PROJECT REQUIREMENTS Technician: Dan Rotty, EIT Checked By: ___~„ Distribution: Bonner Associates -Paul Pitts City of Coppell -Rick Odell C3 Contractors -Taylor Barnes LIMITATIONS: The test results presented herein were prepared based upon the specific satttples provided for testing. We assume no responsibilhy for variation in quality (composition, appearance, perfomnnce, etc.) or any other failure of similar subject rtuuter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the client's to whom they are addressed and shall not be reproduced except in full withom the wriven approval of Fargo Consultants, Inc. Environments/ Services >i Geotechnical Engineering ~ Construction Materia/s Testing