Freeport NIP(7.0)-LR030804RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (In): AIR TEST METHOD: CYLINDER MARKED SET NO. 1 1 1 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MEASURED SLUMP (inches) 1 4.5 2 4.5 3 4.5 1 4 4.5 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS SAMPLE LOCATION: 15' west, 10' north, southeast comer Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 07/31/2003 08/21/2003 08/21/2003 09/18/2003 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 191316 037333 07/24/2003 08/04/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/24/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7 :25am BATCH TIME: 7 :09am TEMPERATURE (F) AIR 80 F CONCRETE: 86 F TRUCK NO: 110 TICKET NO: 117515 AIR CONTENT 3.7 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: South half of south parking lot, Building Column Line MM to NN AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 103180 COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 3650 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 6 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 4000 psi 28 Days 5" maximum 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 2 1 5.0 2 2 5.0 2 3 5.0 2 4 5.0 Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 07/31/2003 08/21/2003 08/21/2003 09/18/2003 PROJECT DATA REPORT OF TESTS AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 89570 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: 191316 037333 07/24/2003 08/04/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/24/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 8:50am BATCH TIME: 8 :35am TEMPERATURE (F) AIR 84 F CONCRETE: 86 F TRUCK NO: 108 TICKET NO: 117531 AIR CONTENT 3.7 UNIT WEIGHT (pci): NA OVERALL PLACEMENT LOCATION: South half of north parking lot, Building Column Line Z to LL SAMPLE LOCATION: 10' east, 10' north of southwest corner COMPRESSIVE STRENGTH (Pd) FRACTURE TYPE 3170. Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 6 RoneEngineers A:LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CYLINDER MARKED SET NO. 3 3 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 3 1 5.0 07/31/2003 5.0 08/21/2003 5.0 08/21/2003 3 4 5.0 09/18/2003 Water added at site: 5 gallons PROJECT DATA REPORT OP TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) SAMPLE LOCATION: 75' east, 15' north of southwest corner AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 84970 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/24/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 9:3Oam BATCH TIME: 9: 148111 TEMPERATURE (F) -AIR 86 F CONCRETE: 88 F TRUCK NO: 102 TICKET NO: 117537 AIR CONTENT 4.0 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: South half of north parking lot, Building Column Line Z to LL COMPRESSIVE STRENGTH (psi) 3000 191316 037333 07/24/2003 08/04/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 3 of 6 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. MEASURED SLUMP (Inches) 4 1 4.5 4 2 4.5 4 3 4.5 4 4 4.5 4000 psi 28 Days 5" maximum 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 DATE TESTED 07/31/2003 08/21/2003 08/21/2003 09/18/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. -in.) AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 92530 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 Report No.: 191316 Project No.: 037333 Date of Service: 07/24/2003 Report Date: 08/04/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/24/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 10:15am BATCH TIME: 9:53am TEMPERATURE (F) AIR 86 F CONCRETE: 89 F TRUCK NO: 102 AIR CONTENT 3.5 TICKET NO: 117545 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: South half of north parking lot, Building Column Line Z to LL SAMPLE LOCATION: 100' east, 10' south of northwest corner COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 3270 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 4of6 RoneEngineers A LEIGH COMPAN Y Client: Duke Realty Services, LP Attn: Mr, Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. MEASURED SLUMP (inches) 5 1 5.0 5 2 5.0 5 3 5.0 5 4 5.0 Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" maximum 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 07/31/2003 08/21/2003 08/21/2003 09/18/2003 PROJECT DATA REPORT OF TESTS MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/24/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 10:50am TEMPERATURE (F) AIR 86 TRUCK NO: 108 AIR CONTENT 3.8 OVERALL PLACEMENT LOCATION: South half of north parking lot, Building Column Line Z to LL SAMPLE LOCATION: 150' east, 20' north of southwest corner AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 84765 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. BATCH TIME: 10:32am F CONCRETE: 89 F TICKET NO: 117553 UNIT WEIGHT (pci): NA COMPRESSIVE STRENGTH (psi) 3000 191316 037333 07/24/2003 08/04/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page5of6 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (In): AIR TEST METHOD: CYLINDER MARKED SET NO. 6 1 5.0 6 2 5.0 6 3 5.0 6 4 5.0 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" maximum 3 -6 %0 ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 07/31/2003 08/21/2003 08/21/2003 09/18/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections Report No.: Project No.: Date of Service: Report Date: MIX DESIGN LD.: 7752 PLACEMENT DATE: 07/24/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 11 :S0am BATCH TIME: 11:33am TEMPERATURE (F) AIR 90 F CONCRETE: 90 F TRUCK NO: 103 TICKET NO: 117564 AIR CONTENT 4.0 UNIT WEIGHT (pci): NA OVERALL PLACEMENT LOCATION: South half of north parking lot, Building Column Line Z to LL SAMPLE LOCATION: 200' east, 10' south of northwest corner AGE (days) 7 28 28 56 Started: 6:30am Finished: 2:30pm MAXIMUM LOAD (ibs. force) 92595 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 COMPRESSIVE STRENGTH (pal) 191316 037333 07/24/2003 08/04/2003 FRACTURE TYPE 3270 Unbonded Cap K. Scott Watson, AET CMT Operations Manager Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 6 of 6 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP Test Methods: ASTM D 2922 ASTM D 3017 M/D No. 1 TEST NO Freeport 10 500 Freeport Parkway Coppell, TX Perform In -Place Density Test in accordance with ASTM Standards. Dark Brown Clay Description TEST LOCATION Backfill 1 Inside Building leaveout, Column Line A.3 at Line 12, final Backfill 2 Inside Building leaveout, Column Line A.3 at Line 14, final Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, 12 (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Pacheco Koch Consulting Engineers PROJECT DATA Gauge: Troxler 3430 Gauge Serial No: 32720 Test Mode: DT MOISTURE DENSITY RELATIONS Maximum Moisture Density pct FIELD DENSITY TESTS Started: 7:30am PROBE DEPTH Test results on this report meet project specification. (1) Engineering Analyst (1) City of Coppell Bldg. Inspections 19.5 104.5 M/D No. 6" 1 23.1 6" 1 24.3 Finished: 1:00pm IN -PLACE DENSITY TESTING Previous: 660 Report No.: 191707 Project No.: 037333 Date of Service: 07/31/2003 Report Date: 08/04/2003 Standard Counts Moisture Density Current: 652 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 +3 and above 122.9 Current: 3064 Previous: 3074 Protect Requirements Moisture Density 121.0 98.3 98.9 K. Scott Watson, AET CMT Operations Manager 92 -96 MOISTURE WET DENSITY DRY DENSITY DENSITY (pct) (pcO max) 94 95 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 07DD Page 1 of 1