Freeport NIP(7.0)-LR030806RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. 1 1 3% 6% AIR CONTENT 4.6 UNIT WEIGHT (pct): NA MEASURED SLUMP (inches) DATE TESTED 1 1 4.00 08/05/2003 2 4.00 08/26/2003 3 4.00 08/26/2003 1 4 4.00 09/23/2003 Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA SAMPLE LOCATION: REPORT OF TESTS OVERALL PLACEMENT LOCATION: North half of south parking lot, Building Column Line GO to LL Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/29/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 8:1 0am BATCH TIME: 7:56am TEMPERATURE (F) AIR 78 F CONCRETE: 90 F TRUCK NO: 1 12 TICKET NO: 117656 AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 100250 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 10' west, 10' north of southeast comer COMPRESSIVE STRENGTH (psi) 191554 037333 07/29/2003 08/06/2003 FRACTURE TYPE 3550 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 1 of 5 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 2 5.00 2 3 5.00 2 4 5.00 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. 2 1 5.00 Duke Realty Services, LP 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 08/05/2003 08/26/2003 08/26/2003 09/23/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/29/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 9:15am BATCH TIME: 9:OOam TEMPERATURE (F) AIR 82 F CONCRETE: 90 F TRUCK NO: 112 TICKET NO: 117666 AIR CONTENT 3.9 OVERALL PLACEMENT LOCATION: North half of south parking lot, Building Column Line GG to LL SAMPLE LOCATION: 75' west, 15' north of southeast corner AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 86245 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 191554 037333 07/29/2003 08/06/2003 UNIT WEIGHT (pct): NA COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 3050 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 2of5 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: AIR Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 3 1 4.50 3% 6% AIR CONTENT 4.6 UNIT WEIGHT (pct): NA DATE TESTED 08/05/2003 3 2 4.50 08/26/2003 3 3 4.50 08/26/2003 3 4 4.50 09/23/2003 PROJECT DATA REPORT OF TESTS OVERALL PLACEMENT LOCATION: North half of south parking lot, Building Column Line GG to LL Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) SAMPLE LOCATION: 125' west, 10' south of northeast corner AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 104335 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/29/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 10:1 Oam BATCH TIME: 9:4Sam TEMPERATURE (F) AIR 84 F CONCRETE: 89 F TRUCK NO: 120 TICKET NO: 117675 COMPRESSIVE STRENGTH (psi) 191554 037333 07/29/2003 08/06/2003 FRACTURE TYPE 3690 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 3 of 5 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 4 1 4 2 4 3 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (Inches) Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 5.00 08/05/2003 5.00 08/26/2003 5.00 08/26/2003 4 4 5.00 09/23/2003 Water added at site: 5 gallons PROJECT DATA REPORT OF TESTS SAMPLE LOCATION: 30' east, 10' south of northwest comer AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 86775 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/29/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 11: l5am BATCH TIME: 10:54am TEMPERATURE (F) AIR 86 F CONCRETE: 90 F TRUCK NO: 1 13 TICKET NO: 117686 AIR CONTENT 4.6 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North half of south parking lot, Building Column Line GG to LL COMPRESSIVE STRENGTH (psi) 3070 191554 037333 07/29/2003 08/06/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 4 of 5 RoneEngiheers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 5 1 5 2 5 3 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, IX (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (I) Potter Concrete Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" maximum ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED 5.00 08/05/2003 5.00 08/26/2003 5.00 08/26/2003 5 4 5.00 09/23/2003 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections REPORT OF TESTS Started: 7:30am MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/29/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 12:OOpm BATCH TIME: 11 :48am TEMPERATURE (F) AIR 92 F CONCRETE: 92 F TRUCK NO: 120 TICKET NO: 117694 3% 6% AIR CONTENT 3.8 UNIT WEIGHT (pet): NA OVERALL PLACEMENT LOCATION: North half of south parking lot, Building Column Line GG to LL SAMPLE LOCATION: Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 56 Finished: 2:30pm MAXIMUM LOAD (lbs. force) 86685 Report No.: Project No.: Date of Service: Report Date: 10' east, 10' north of southwest comer COMPRESSIVE STRENGTH (psi) 191554 037333 07/29/2003 08/06/2003 FRACTURE TYPE 3070 Unbonded Cap K. Scott atson, AET CMT Operations Manager Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 5 of 5 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services. Freeport 10 500 Freeport Parkway Coppell, TX Perform In -Place Density Test in accordance with ASTM Standards. CONTRACTOR: Duke Realty Services, LP Test Methods: ASTM D -2922 ASTM D -3017 M/D No. Description TEST NO 1 Dark Brown Clay Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Pacheco Koch Consulting Engineers TEST LOCATION PROJECT DATA Gauge: Troxler 3430 Gauge Serial No: 32720 Test Mode: DT Backfill 1 Outside panel, Column Line A.3 at Line 15, final Backfill 2 Outside panel, Column Line A.3 at Line 13, final Bacicfill 3 Outside panel, Column Line B.9 at Line 15, final MOISTURE DENSITY RELATIONS Maximum Moisture Density pcf Started: FIELD DENSITY TESTS Test results on this report meet project specification. See report #191707 for technician time (1) Engineering Analyst (1) City of Coppell Bldg. Inspections Finished: IN -PLACE DENSITY TESTING Standard Counts Moisture Density Current: 652 Previous: 660 Report No.: Project No.: Date of Service: Report Date: 6" 1 19.9 119.2 6" 1 20.6 122.8 6" 1 19.7 120.1 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 191705 037333 07/31/2003 08/06/2003 Current: 3064 Previous: 3074 Project Requirements Moisture Density 19.5 104.5 Optimum+ 95 min PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY DEPTH No. Oct) (pci) max) 99.4 101.8 100.3 K. Scott Watson, AET CMT Operations Manager 95 97 96 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Pone Engineers, Ltd. 07DD Page 1 of 1 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Reinforcing Steel Inspection Technician Time: 1:OOpm 2:OOpm Page 1 of 2 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (I) City of Coppell Engineering Dept. (1) Pacheco Koch Consulting Engineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 REPORT OF REINFORCING STEEL INSPECTION Report of Inspection (1) Engineering Analyst (1) City of Coppell Bldg. Inspections Report No.: Project No.: Date of Service: Report Date: On this date, a Rone Engineers, Ltd. representative(s) arrived on site as scheduled to perform Reinforcing Steel Inspection. The results are attached. 191706 037333 07/31/2003 08/06/2003 Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 99DD Pace 1 of 1 Items Inspected: Conforming Non Conforming Items Inspected: Conforming Non Conforming Items Inspected: Conforming Non Conforming Placing Drawings Approved Bar Length and Shape tt-- Column Ties Properly Tied and Spaced Bar Size L/ Proper Bar Placement L. Stirrup Spacing and Type i Bar Grade L! Properly Tied L/ Lapped Splices Bars Clean t/ Dowel Bars in Place 1! Welded Splices Form Clean Proper Bar Supports Mechanical Splices Number Bars Proper Cover Ro =gin Inspector's Signature: C-1 6300 Rothway, Suite 150 Houston, Texas 77040 (713) 996 -9979 8908 Ambassador Row Dallas, Texas 75247 (214) 630-9745 Report of (Like Steel Inspection Client: D ik e Report No.: i Qt i 70 b ProjectNo.: e9373 Project: Freeport /O Date of Service: 7 '3/ -0 3 Page of j_ Locations and Items Inspected: r or f+ /4q/ e o Alorft. Perk'; r.. /O/ 2314 Cr) /m,,- Lines Z ,ev C c Discrepancies /Comments: $t 2 4 ,al? w et e n c e e Qa'Ye nr 7 Ct eicre /r /2 /'r e n e.- LIMITATIONS: The cox results presented herein were prepared based upon the specific samples provided for tewing. We assume no ksponaibiliiy for variation in quality (composition 20 14 (7/03) appearance. perfonna Ue. etc. I or any other feature eln imdnr, neieet minter prodded by peso conditions or over which we have no control. Our letters and repo are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rose Engineers. LW. 2696 Gravel Drive Fort Worth, Texas 76118 (817) 284-1318 Time: l o o PN^ to 3a Client/Contractor Signature: Client/Contractor Copied with Results: Yes No