Gateway BP(2.3)-CS030721WRIGHT GROUP
1110 South Elm Street, Carrollton, Texas 75006
Architects-Planners, PLLC
tel. 972.242.1015, fax. 972.446.8013
July 21, 2003
Mr. Kenneth Griffin, P.E.
City of Coppell
255 Parkway Boulevard
P.O. Box 478
Coppell, Texas 75019-44,09
Re: Pavement Design, 555 Dividend Drive, Coppell, Texas 75019.
Dear Mr. Griffin:
Wright Group Architects Planners would like to submit an alternative pavement design for Gateway 1 Office
Building - Additional Parking to match existing site paving. For the new parking area, the alternative
design is 6 inch thick 4000 PSi compressive strength concrete with #3 bars, 24 inch O.C.E.W. on
compacted subgrade in lieu of the 6 inch thick 3000 PSI compressive strength concrete with #3 bars, 24
inch O.C.E.W. on 6 inch lime stabilized subgrade as shown in Appendix C of the City of Coppell
Subdivision Ordinance.
Respectfully,
err ~ '