Loading...
SC-Coppell HS-CS 871209817 336 -5773 J TEAGUE NALL AND PERKINS J C O N S 11 L T 1 N G E N G 1 N E E R S December 9, 1987 ..� Mr. Mike Elmore DEC 141987 SHWC, Inc. 5601 McArthur Blvd. P.O. Box 619087 Dallas, Texas 75261 �• itXHS Re: Coppell High School Shop Drawings for Water and Sewer Dear Mike: In response to your request to review the submitted shop drawings for water and sewer improvements for the Coppell High School, we offer the following comments: The iron gate valves manufactured by Kennedy Valve Company have been rejected because they do not meet the AWWA -C- 509 -80 Spec as called for on your Architectural Sheet 2.24 of City Water Details. Ui,, fr'r V'� 2. Tapping sleeves shall be stainless steel if' the pipe to be tapped is PVC; however, gray cast iron may be used if the water line to be tapped is ductile cast iron pipe. Therefore, before purchase of the tapping sleeves are made by the contractor, verification should be made in the field as to the material of the existing water line. 3. Fire hydrant details furnished by Mueller Company is in compliance with the AWWA standard C -502 as �V 1- specified in the City of Coppell details. However, " final approval regarding style and design should be made by the City of Coppell before any purchase is made. 4. In reference to those water meters to be installed on the site, the City of Coppell Subdivision Ordinance requires that all meters "be purchased from the City or shall be of materials approved by the City." Therefore no approval or rejection can be made regarding this item. 5. Other items submitted (i.e. piping, service saddles, double check, and master meter assemblies) appear to be in compliance with the City of Coppell's specifications. nr0 Street F )rI . 1 . — ..a5 7,,102 Mr. Mike Elmore SHWC, Inc. December 9, 1987 Page Two Mike, even though we have reviewed all of these submittals to see if they comply with the specifications, we strongly recommend that final approval be given by the City of Coppell since these submittals represent materials to be installed in improvements which are considered "public" and, therefore, will be maintained and owned by the City of Coppell. Therefore, our review and comments of these submittals should only be considered as a cursory review and not final approval for construction. We would also encourage that the contractor obtain a copy of the City of Coppell Subdivision Ordinance dated November 1985 and referenced as Ordinance No. 341 for any additional information regarding the construction of public water and sewer improvements in the City of Coppell. We feel like this may assist him in addition to discussing with the City those improvements which the City Inspectors will be inspecting on this job. If we can be of any further assistance to you, please feel free to call. Sincerely, TEAGUE NALL AND PERKINS, INC. Tom Rutledge STR /11 Enclosures cc: Spaw Glass, Inc. John Nall, Jr.