Loading...
DR0001-LR030531TERRA MAR GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORTWORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: ( 972) 488 -8800 fax:(972) 488 -8080 In -Place Soil Moisture /Density Tests by Nuclear Method Client: City of Coppell Report Distribution: (1) City of Coppell Project: MacArthur Samuel Drainage Project TMI Report No.: 45429 -017 Report Date: 05/31/2003 pecl Ica ions I est uata Percent Compaction: +95% min Date Tested: 05/28/2003 Moisture Content: opt -2% to +4% Technician: Mohammed A. Kashem Test results on this report meet project specification. Test Method(s): ASTM D -2922, ASTM D -3017 Gauge: Troxler Gauge SN: 33086 Std. Density Count: 2806 Std. Moisture Count: 714 TERRA -MAR, INC. Mike Fuller Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. msso Page I of I Optimum Maximum Dry Curve No. Test Method Material Description Moisture % Density pcf 9734 ASTM D -698 -A Brownish Gray Sandy Clay w/ Concrete Fragments 13.5 112.0 Test Elevation Ref. Probe Percent Wet Density Dry Density Percent No or Lift Location Curve Depth Moisture (pcf) (pcf) Density 19.0 Grade Street cut for storm sewer at North bound 9734 6" 12.1 120.2 107.2 95.7 MacArthur at right lane at 300' North from Samuel Blvd. 20.0 Grade Street cut for storm sewer at South bound 9734 6" 11.5 119.2 106.9 95.4 MacArthur at left turn lane at 90' North from Samuel Blvd. Test results on this report meet project specification. Test Method(s): ASTM D -2922, ASTM D -3017 Gauge: Troxler Gauge SN: 33086 Std. Density Count: 2806 Std. Moisture Count: 714 TERRA -MAR, INC. Mike Fuller Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. msso Page I of I