Loading...
DR0001-LR030611Client: City of Coppell Project: MacArthur Samuel Drainage Project TMI Report No.: 45429 -021 Report Date: 06/11/2003 GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax.(972) 488 -8080 Concrete Compression Test Report Report Distribution: (1) City of Coppell Strength 3000 psi @ 28 Days Placement Date 06/04/2003 Slump 1 in min 3 in max Sampled By John Restau Air Content 3 % min 5 % max Weather Pt. Cloudy Concrete Temperature n/a Supplier /Mix Lattimore Materials /1263 Ambient Temperature n/a Air Content Method ASTM C -231 - Ticket Number: 3160458 Time Batched: 12:30 pm Time Sampled: 1:05 pm Slump: 5.5 in" Air Content: 5.8 %* Unit Weight: n/a Concrete Temperature: 89° F Ambient Temperature: 87° F Yardage (c.y.): 4 of 4 Placement Location: South bound MacArthur, outside lane, approximately 20' North of intersection of Cribbs & MacArthur Sample Location: Paving, South bound lane, MacArthur, outside lane, 20' North of Cribbs An asterisk (') appears next to field data which does NOT meet specifications. CortCteteCompressian- TesY.R � esults v Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 4�& TERRA -MAR, INC. Mike Fuller Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. nisso Page 1 of 1 Cylinder Date Age Max Load Area ( days) ( lbs. force) (sq.in.) Stren th (Psi Fracture Type Set # # Test 1 06040301 06/11/2003 7 81500 28.27 2880 unbonded cap 1 06040302 07/02/2003 28 1 06040303 07/02/2003 28 1 06040304 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 4�& TERRA -MAR, INC. Mike Fuller Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. nisso Page 1 of 1 Client: City of Coppell Project: MacArthur Samuel Drainage Project TMI Report No.: 45429 -006 Report Date: 06/11/2003 GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax: (972) 488 -8080 Concrete Compression Test Report Report Distribution: (1) City of Coppell Strength 3000 psi @ 28 Days Placement Date 05/14/2003 Slump 1 in min 3 in max Sampled By Zuhair Shubbar Air Content 3 % min 5 % max Weather Cloudy Concrete Temperature n/a Supplier /Mix Lattimore Materials /1263 Ambient Temperature n/a Air Content Method ASTM C -231 -B ield Data Set Ticket Number: 3159469 Time Batched: 2:37 pm Time Sampled: 3:15 pm Slump: 3 in Air Content: 4.0% Unit Weight: n/a Concrete Temperature: 82° F Ambient Temperature: 84° F Yardage (c.y.): 6 of 6 Placement Location: Paving and electric pole Sample Location: MacArthur & DeForest u -turn intersection & electric pole in the corner of middle islane in same street C oncrete Compression Test Results Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA -MAR, INC. The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of Th11. Pagc I ul l aissD n�Icu rviauayci Cylinder y Date Age Max Load (Ibs. force) Area (sq.in.) Strength (psi) Fracture Type Set # # Test ( days) 1 05140301 05/21/2003 7 100480 28.27 3550 unbonded cap 1 05140302 06/11/2003 28 141420 28.27 5000 unbonded cap 1 05140303 06/11/2003 28 139580 28.27 4940 unbonded cap 1 05140304 Hold 28 day average 4970 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA -MAR, INC. The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of Th11. Pagc I ul l aissD n�Icu rviauayci