Loading...
DR0001-LR030729Client: City of Coppell Project: Cribbs Alley TMI Report No.: 51538 -002 Report Date: 07/29/2003 Report Distribution: (1) City of Coppell Strength Slump Air Content Concrete Temperature .Ambient Temperature 4200 psi @ 28 Days 3 in min 5 in max 3 % min 5 % max n/a n/a Placement Date Sampled By Weather Supplier /Mix Air Content Method 07/21/2003 Greg Mason Clear Lattimore Materials /1701 ASTM C -231 -B ^ b 8 Q a J . ..*a"" `1'�� €n asbh- r.,�., ��� - -_ Ticket Number: 3162853 Time Batched: 3:00 pm Time Sampled: 3:40 pm Slump: 4.5 in Air Content: 2.8 %" Unit Weight: n/a Concrete Temperature: 98° F Ambient Temperature: 101' F Yardage (c.y.): 4 of 4 Placement Location: Inlet Sample Location: North bound lane, inlet North of SE corner of MacArthur at Samuel South bound lane inlet North of MacArthur at Cribbs, alley approach North of South bound inlet, North of MacArthur & Cribbs An asterisk (`) appears next to field data which does NOT meet specifications. Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 TERRA -MAR, INC. Fracture Type unbonded cap The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORTWORTH HOUSTON AUSTIN LONGVIEW 11050Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax:(972) 488 -8080 Concrete Compression Test Report 0JSS Page I or I Cylinder Age Max Load Area Stren ggth Set # # Test Date (days) (lbs. force) (sq.in.) (psp 1 07210301 07/28/2003 7 108650 28.27 3840 1 07210302 08/18/2003 28 1 07210303 08/18/2003 28 1 07210304 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 TERRA -MAR, INC. Fracture Type unbonded cap The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORTWORTH HOUSTON AUSTIN LONGVIEW 11050Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax:(972) 488 -8080 Concrete Compression Test Report 0JSS Page I or I