DR0001-LR030730,R Client: City of Coppell Project: Cribbs Alley TMI Report No.: 51538 -003 Report Date: 07/30/2003 Report Distribution: (1) City of Coppell Strength Slump Air Content Concrete Temperature 3000 psi @ 28 Days 3 in min 5 in max n/a n/a Ambient Temperature n/a Placement Date Sampled By Weather Supplier /Mix Air Content Method 07/22/2003 Attef Abushakra Pt. Cloudy Lattimores Materials /41701 ASTM C-231 -B Placement Location: Paving, alley Sample Location: Paving, alley located 115' North of Cribbs Dr. & MacArthur off the West side of MacArthur extends from West edge of MacArthur to 45' West of MacArthur An asterisk (') appears next to field data which does NOT meet specifications. "vs� i'�a -a4'�b a.x: r ° ?f ''`�a '`S�GhB et'.'',fll Iu",a.r„a�+,ie !. .. ^.E: ... x, :.. y.x. a,.' s rk Fly Set # Cylinder # Test Date Age Max Load Area Strength Fracture ( days) ( Ib s. force) ( sq.in.) (p si) Type 1 07220301 07/29/2003 7 100390 28.27 3550 unbonded cap 1 07220302 08/19/2003 Ticket Number: 3162919 Time Batched: 3:44 pm Time Sampled: 4:05 pm Slump: 6 in` Air Content: 3.2% Unit Weight: n/a Concrete Temperature: 98° F Ambient Temperature: 103° F Yardage (c.y.): 3.50 of 3.50 Placement Location: Paving, alley Sample Location: Paving, alley located 115' North of Cribbs Dr. & MacArthur off the West side of MacArthur extends from West edge of MacArthur to 45' West of MacArthur An asterisk (') appears next to field data which does NOT meet specifications. "vs� i'�a -a4'�b a.x: r ° ?f ''`�a '`S�GhB et'.'',fll Iu",a.r„a�+,ie !. .. ^.E: ... x, :.. y.x. a,.' s rk Fly Set # Cylinder # Test Date Age Max Load Area Strength Fracture ( days) ( Ib s. force) ( sq.in.) (p si) Type 1 07220301 07/29/2003 7 100390 28.27 3550 unbonded cap 1 07220302 08/19/2003 28 1 07220303 08/1912003 28 1 07220304 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 TERRA -MAR, INC. Mike Fuller Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax:(972) 488 -8080 Concrete Compression Test Report 01550 Page I of I