DR0001-LR030731TERRA4WAR
Client: City of Coppell
Project: Cribbs Alley
TMI Report No.: 51538 -006
Report Date: 07/31/2003
Report Distribution: (1) City of Coppell
Strength
Slump
Air Content
Concrete Temperature
Ambient Temperature
3000 psi @ 28 Days
3 in min 5 in max
n/a
n/a
n/a
Placement Date
Sampled By
Weather
Supplier /Mix
Air Content Method
07/23/2003
Steve Pickett
Clear
Lattimores Materials /1701
ASTM C -231 -B
$&'+."" 1 =aar{i e cG s E ' r4 ',rS'It 3a. D� R €Pnw;':.
b " f $ + r�F' ; k'G"�4'�
"x- 'f: ar,.a +a, r i?' a �3jn xic'f'�sa i. aa. .. t n
Ticket Number: 31622992 Time Batched: 3:37 pm Time Sampled: 4:15 pm
Slump: 3 in Air Content: 4.0% Unit Weight: n/a
Concrete Temperature: 94' F Ambient Temperature: 94' F Yardage (c.y.): 6 of 6
Placement Location: Curb & gutter for storm drain & sidewalk
Sample Location: South bound lane, MacArthur, North of Cribbs
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231
TERRA -MAR, INC.
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is strictly prohibited without the express written consent of TMI.
GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax: (972) 488 -8080
Concrete Compression Test Report
oissu Page I of I
rrolect Manager
Cylinder
Age
Max Load Area
Stren
Fracture
Set #
#
Test Date
(d ays)
(lbs. force) ( sq.in.)
(psil
Type
1
07230301
07/30/2003
7
100820 28.27
3570
unbonded cap
1
07230302
08/20/2003
28
1
07230303
08/20/2003
28
1
07230304
Hold
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231
TERRA -MAR, INC.
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is strictly prohibited without the express written consent of TMI.
GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax: (972) 488 -8080
Concrete Compression Test Report
oissu Page I of I
rrolect Manager