DR0001-LR030805Client: City of Coppell
Project: Cribbs Alley
TMI Report No.: 51538 -001
Report Date: 08/05/2003
Report Distribution: (1) City of Coppell
Strength
Slump
Air Content
Concrete Temperature
Ambient Temperature
4200 psi @ 28 Days
3 in min 5 in max
3 % min 5 %max
n/a
n/a
Placement Date
Sampled By
Weather
Supplier /Mix
Air Content Method
07/18/2003
Attef Abushakra
Pt, Cloudy
Lattimore Materials /1701
ASTM C -231 -B
RAMONE
Ticket Number: 7129327 Time Batched: 4:10 pm Time Sampled: 4:45 pm
Slump: 1 in' Air Content: 3.0% Unit Weight: n/a
Concrete Temperature: 103° F Ambient Temperature: 101* F Yardage (c.y.): 6.50 of 6.50
Placement Location: Two inlets located approximately 20' North of MacArthur Blvd. & Cribbs Dr. on both East & West edge of
MacArthur
Sample Location: Approximately 20' North of MacArthur Blvd. & Cribbs Dr. on both East & West edge of MacArthur
An asterisk (') appears next to field data whi does NOT meet specifications. !'
e�t.. .�'.s"..
Set #
Cylinder
#
Test Date
Age Max Load Area
( days) f ibs. force) ( sq.in.)
Stren th Fracture
(psi8 Type
1
07180301
07/25/2003
7 104900 28.27
3710 unbonded cap
1
07180302
08/15/2003
28
1
07180303
08/15/2003
28
1
07180304
Hold
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231
w
TERRA -MAR, INC. Mike Fuller
Project Manager
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is strictly prohibited without the express written consent of TMI.
GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax: (972) 488 -8080
Concrete Compression Test Report
Page 1 of I
OISSD