Loading...
DR0001-LR030819TERRA-MAR Client: City of Coppell Project: Cribbs Alley TMI Report No.: 51538 -001 Report Date: 08/19/2003 GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORTWORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax:(972) 488 -8080 Concrete Compression Test Report Report Distribution: (1) City of Coppell Strength 4200 psi @ 28 Days Placement Date 07/18/2003 Slump 3 in min 5 in max Sampled By Attef Abushakra Air Content 3 % min 5 % max Weather Pt. Cloudy Concrete Temperature n/a Supplier /Mix Lattimore Materials /1701 Ambient Temperature n/a Air Content Method ASTM C -231 -B e a m> a Ticket Number: 7129327 Time Batched: 4:10 pm Time Sampled: 4:45 pm Slump: 1 in" Air Content: 3.0% Unit Weight: n/a Concrete Temperature: 103° F Ambient Temperature: 101' F Yardage (c.y.): 6.50 of 6.50 Placement Location: Two inlets located approximately 20' North of MacArthur Blvd. & Cribbs Dr. on both East & West edge of MacArthur Sample Location: Approximately 20' North of MacArthur Blvd. & Cribbs Dr. on both East & West edge of MacArthur An asterisk (`) appears next to field data which does NOT meet specifications. Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA -MAR, INC. Mike Fuller Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. oissD Page I of I Cylinder Age Max Load ( lbs. force) Area ( sq.in.) Strength (p si Fracture Type Set # # Test Date ( days) 1 07180301 07/25/2003 7 104900 28.27 3710 unbonded cap 1 07180302 08/15/2003 28 119830 28.27 4240 unbonded cap 1 07180303 08/15/2003 28 121420 28.27 4290 unbonded cap 1 07180304 Hold 28 day average 4270 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA -MAR, INC. Mike Fuller Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. oissD Page I of I