SC-Cottonwood E9-LR 951016FUGRO- McCLELLAND (SOUTHWEST), INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (214) 484 -8301; Fax (214) 620.7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Coppell ISD Report Date: October 16, 1995
PROJECT: Cottonwood Elementary School, Coppell, Texas Project No.: 0751 -2055
SAMPLE D ATE: September 14, 1995 1
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. ( °F):
CONCRETE TEMP. ( °F):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
K A Sparks Contractors, Inc
313977
CONCRETE SUPPLIER:
82
PLANT/TRUCK:
88
MIX ID NUMBER:
8:28 am
AIR ( %) (ASTM C -231)
9:30 am
WATER ADDED (gal):
partly cloudy
SLUMP (inches) (ASTM C -143)
Circle drive, west entry
135 feet from Minyard
Express Concrete
4/385
9339
6
10
5 1/2"
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 22 11 , 28.27 square inches
CYLINDER
NUMBER
AGE
(days)
DATE
TESTED
TOTALLOAD
(pounds)
COMPRESSIVE
STRENGTH
(psi)
REQUIRED COMPRESSIVE
STRENGTH
(p
CWS 197
7
09/21/95
86000
3043
3000/28 days
CWS 198
28
10/12/95
113000
3998
CWS 199
28
10/12/95
111000
1 3927
CWS 200
Hold
Specifications: Making & Curing: ASTM C -3I Testing Methods: ASTM C. 143. ASTM C -39
REMARKS:
Technician: David Peters FUGRO- McCLELLAND ( SOUTHWEST), INC.
Checked By:
SMH/rm
Distribution: Coppell ISD - Mickey Harper
City of Coppell - Garreth Campbell
K A Sparks Construction, Inc. - E. J. Williams
SHW Group - Mike Elmore
SHW Group - Joe Craddock
i can
FUGRO-McCLELLAND (SOUTHWEST), INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (214) 484 -8301; Fax (214) 620 -7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Coppell ISD Report Date: October 116, 1995
PROJECT: Cottonwood Elementary School, Coppell, Texas Project No.: 0751 -2055
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. ( ° F):
CONCRETE TEMP. ( °F):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
K A Sparks Contractors, Inc
313934
CONCRETE SUPPLIER:
78
PLANT /TRUCK:
84
MIX ID NUMBER:
7:05 am
AIR ( %) (ASTM C -231)
8:00 am
WATER ADDED (gal):
partly cloudy
SLUMP (inches) (ASTM C -143)
Circle drive around,
north parking lot at west end crossover
Express Concrete
4/
9339
5
10
4 1/2"
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" a 12", 28.27 square inches
CYLINDER
NUMBER
AGE
(days)
DATE
TESTED
TOTAL LOAD
(pounds)
COMPRESSIVE
STRENGTH
(psi)
REQUIRED COMPRESSIVE
STRENGTH
(psi)
CWS 193
7
09/21/95
87000
3078
3000/28 days
CWS 194
28
10/12/95
109000
3856
CWS 195
28
10/12/95
1 107000
1 3785
CWS 196
Hold
Specifications: Making & Curing: ASTM C -31 Testing Methods: ASTM C.143. ASTM C39
REMARKS:
Technician: David Peters FUGRO- McCLELLAND (SOUTHWEST), INC.
Checked By:
SMH/rm
Distribution: Coppell ISD - Mickey Harper
City of Coppell - Garreth Campbell
K A Sparks Construction, Inc. - E. J. Williams
SHW Group - Mike Elmore
S14W Group - Joe Craddock