Loading...
DR0001-LT030825TIERRAAY M Client: City of Coppell Project: Cribbs Alley TIM Report No.: 51538 -006 Report Date: 08/25/2003 Report Distribution: (1) City of Coppell Strength Slump Air Content Concrete Temperature Ambient Temperature 3000 psi @ 28 Days 3 in min 5 in max n/a n/a n/a Placement Date Sampled By Weather Supplier /Mix Air Content Method 07/23/2003 Steve Pickett Clear Lattimores Materials /1701 ASTM C -231 -B Ticket Number: 31622992 Time Batched: 3:37 pm Slump: 3 in Air Content: 4.0% Concrete Temperature: 94° F Ambient Temperature: 94° F Placement Location: Curb & gutter for storm drain & sidewalk Sample Location: South bound lane, MacArthur, North of Cribbs Time Sampled: 4:15 pm Unit Weight: n/a Yardage (c.y.): 6 of 6 Set # Cylinder # Test Date Age (days) Max Load (lbs. force) Area (sq. in.) Siren In (psp Fracture Type 1 07230301 07/30/2003 7 100820 28.27 3570 unbonded cap 1 07230302 08/20/2003 28 127870 28.27 4520 unbonded cap 1 07230303 08/20/2003 28 137810 28.27 4870 unbonded cap 1 07230304 Hold 28 day average 4700 Normal cylinder size: 6" x 12" Field and laboratory tests by TM are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA -MAR, INC. Mike Fuller Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORTWORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: ( 972) 488 -8800 fax(972) 488 -8080 Concrete Compression Test Report UISSD Page 1 of 1