Freeport NIP(7.0)-LR030821RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER. PLANT: SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. MEASURED SLUMP (inches) 1 1 5.00 Duke Realty Services, LP Potter On site DATE TESTED 07/30/2003 1 2 5.00 08/20/2003 1 3 5.00 08/20/2003 1 4 Hold 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 98930 128970 127430 Average Report No.: Project No.: Date of Service: Report Date: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/23/2003 WEATHER CONDITIONS: Partly Cloudy TIME SAMPLED: 10:2Oam BATCH TIME: 10:04am TEMPERATURE (F) AIR 86 F CONCRETE: 88 F TRUCK NO: 101 TICKET NO: 117493 AIR CONTENT 3.3 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: South half of south parking lot, Building Column Lines LL to MM SAMPLE LOCATION: 15' north, 10' east, southwest corner COMPRESSIVE STRENGTH (Psi) 3500 4560 4510 4540 191272 037333 07/23/2003 08/21/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Roue Engineers, Ltd. 01DD Page 1 of 2 RoneEngineers to A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project. Services: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 4000 psi 28 Days 5" maximum 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 DATE TESTED 2 1 5.00 07/30/2003 2 2 5.00 08/20/2003 2 3 5.00 08/20/2003 2 4 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS SAMPLE LOCATION: 30' east, 20' north, southwest corner Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/23/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 11:3Sam BATCH TIME: 11:14am TEMPERATURE (F) AIR 85 F CONCRETE: 89 F TRUCK NO: 106 TICKET NO: 117503 AIR CONTENT 3.8 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: South half of south parking lot, Building Column Lines LL to MM AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 92145 116710 111635 Average Does not comply with specified strength. Please see report #191220 for technician time. 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 3260 4130 3950 4040 191272 037333 07/23/2003 08/21/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rene Engineers, Ltd. 01DD Page 2 of 2