Freeport NIP(7.0)-LR030819RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: Page 1 of 2 Freeport 10 500 Freeport Parkway Coppell, TX Reinforcing Steel Inspection Report of Inspection On this date, a Rone Engineers, Ltd. representative(s) arrived on site as scheduled to perform Reinforcing Steel Inspection. The results are attached. Technician Time: 2:OOpm 3:OOpm Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 REPORT OF REINFORCING STEEL INSPECTION Report No.: Project No.: Date of Service: Report Date: 192611 037333 08/14/2003 08/19/2003 K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 99DD Page 1 ofl Items Inspected: Conforming Non Conforming Items Inspected: Conforming Non Conforming Items Inspected: Conforming Non Conforming Placing Drawings Approved 4.- Bar Length and Shape Tied Sea Properly Spaced and p Bar Size L/' Proper Bar Placement Stirrup Spacing and Type Bar Grade Gi' Properly Tied L.--- Lapped Splices 1.---- Bars Clean 4/ Dowel Bars in Place V Welded Splices Form Clean L,i Proper Bar Supports Mechanical Splices Number Bars L/ Proper Cover RoneEngineers to A LEIGH COMPANY Client. Aike Project: t r eepons /o 8908 Ambassador Row Dallas, Texas 75247 (214) 630 -9745 Report of Reinforcing Steel Inspection q Report No.: /2 Project No.: 03 7 33 3 Date of Service: y- 0 3 Page of Inspector's Signature: J.6;3-' Time: 2001/n to 2 :3ap,.. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided taunting. We assume no responsibility for variation in quality (composition appearance. performance, rte.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Pone Engineers, Inc. 121 North Rayner Fort Worth, Texas 76111 (817) 831 -6211 Locations and Items Inspected: 4951 gnat W"/ t4/ 2)t4y per ✓4- J Z f' 6;de of Aldo Discrepancies Comments: (/c7,7 '/r 4e' gdeicki a'v ;p1 Vie rP7° /ha P/n Pit Client/Contractor Signature: Client/Contractor Copied with Results: Yes No RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. 5" maximum 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 1 1 4.0 07/28/2003 1 2 4.0 08/18/2003 1 3 4.0 08/18/2003 1 4 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 191074 037333 07/21/2003 08/19/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7:2Oam BATCH TIME: 7:07am TEMPERATURE (F) AIR 78 F CONCRETE: 89 F TRUCK NO: 101 TICKET NO: 117349 AIR CONTENT 3.1 OVERALL PLACEMENT LOCATION: North parking lot, south half, building column line S to Z SAMPLE LOCATION: 15' east, 10' north of southwest corner AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 96080 120135 119900 Average UNIT WEIGHT (pcf): NA COMPRESSIVE STRENGTH (Po) 3400 4250 4240 4250 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 6 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 1 2 2 2 3 4000 psi 28 Days 5" maximum 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 4.5 4.5 4.5 DATE TESTED 07/28/2003 08/18/2003 08/18/2003 2 4 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 8:2Oam TEMPERATURE (F) AIR TRUCK NO: 102 AIR CONTENT 3.4 Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 191074 037333 07/21/2003 08/19/2003 BATCH TIME: 8:12am 80 F CONCRETE: 89 F TICKET NO: 117359 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: North parking lot, south half, building column line S to Z SAMPLE LOCATION: 4b' easl, 4 south corner MAXID UM LOAD (ibs. force) 87220 115180 113465 Average est COMPRESSIVE STRENGTH (psi) 3080 FRACTURE TYPE Unbonded Cap Unbonded Cap bonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 6 RoneEngineers s A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQU STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 3 1 3 2 3 3 3 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter On site IRE MENTS 4000 psi 28 Days 5" maximum 3 %a -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED 4.0 07/28/2003 4.0 08/18/2003 4.0 08/18/2003 4.0 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA TEMPERATURE (F) AIR TRUCK NO: 104 AIR CONTENT 3.0 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 9:3Oam BATCH TIME: 9:12am AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 114650 111045 Average Does not comply with specified strength. 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 Report No.: Project No.: Date of Service: Report Date: 191074 037333 07/21/2003 08/19/2003 82 F CONCRETE: 89 F TICKET NO: 117368 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: North parking lot, south half, building column line 5 to Z SAMPLE LOCATION: 125' east, 20' north of southwest comer COMPRESSIVE STRENGTH (Po) 91340 3230 4050 3930 3990 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap 09/15/2003 56 Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 3 of 6 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR (%n): 3% 6% TEST METHOD: ASTM C -172 ASTM C -31 CYLINDER MARKED SET NO. Duke Realty Services, LP Potter On site ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 4 1 5.0 07/28/2003 4 2 5.0 08/18/2003 4 3 5.0 08/18/2003 5.0 4 4 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 10:4Oam BATCH TIME: TEMPERATURE (F) AIR TRUCK NO: 109 AIR CONTENT 3.7 OVERALL PLACEMENT LOCATION: North parking lot, south half, building column line S to Z REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) SAMPLE LOCATION: 150' east, 10' north of southwest corner AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 81540 108095 109805 Average Does not comply with specified strength. Report No.: Project No.: Date of Service: Report Date: 10:22am 86 F CONCRETE: 91 F TICKET NO: 117380 UNIT WEIGHT (pcf): NA COMPRESSIVE STRENGTH (psi) 2880 191074 037333 07/21/2003 08/19/2003 3820 3880 3850 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap 09/15/2003 56 Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 4 of 6 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIRE STRENGTH: SLUMP (in): AIR CYLINDER MARKED SET NO. 5 1 5.0 5 2 5.0 5 3 5.0 5 4 5.0 Duke Realty Services, LP Potter On site TEST METHOD: 7 TM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) Concrete Compressive Cyl DATE TESTED 07/28/2003 08/18/2003 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630.9745 CONCRETE COMPRESSIVE STRENGTH TEST Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA 08/18/ 28 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 11:30am BATCH TIME: 11:O9am TEMPERATURE (F) AIR 87 F CONCRETE: 92 F TRUCK NO: 104 TICKET NO: 117388 AIR CONTENT 3.9 UNIT WEIGHT (pcf): NA VERALL PLACEMENT LOCATION: orth parking lot, south half, building column line S to Z SAMPLE LOCATION: 125' west, 10' north of southeast corner der 6" x 12" (area 28.27 sq. in.) A E (da 7 MAXIMUM LOAD (lbs. force) 78135 28 104090 56 05985 Ave mply with specified strength. Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (Psi) 191074 037333 07/21/2003 08/19/2003 FRACTURE TYPE 2760 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. o1DD Page 5 of 6 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: ASTM C -172 CYLINDER MARKED SET NO. 6 1 5.0 6 2 5.0 6 3 5.0 6 4 5.0 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 07/28/2003 08/18/2003 08/18/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MIX DESIGN I.D.: 7752 PLACEMENT DATE: 07/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 12: BATCH TIME: 12:1$pm TEMPERATURE (F) AIR 92 F CONCRETE. 92 F TRUCK NO: 101 TICKET NO: 117397 AIR CONTENT (°k): 3.0 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: North parking lot, south half, building column line S to Z SAMPLE LOCATION: 100' west, 10' south of northeast corner AGE (days) 7 28 28 Does not comply with specified strength. Started: 7:OOam Finished: 3:OOpm (I) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections MAXIMUM LOAD (lbs. force) 87880 109345 111360 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 3110 3870 3940 3910 191074 037333 07/21/2003 08/19/2003 K. Scott Watson, AET CMT Operations Manager FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap 09/15/2003 56 Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 6 of 6