PA9901-LR010618A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100 Concrete Compression Test
Dallas, Texas 75229 Report
(972) 620 -8911
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
Our Report No.: 00931 -105
Issue Date: 06/18/2001
FIELD DATA
Placement Location: BLEACHER PAD; 100'W & 150'S FROM THE SW GOAL OF SOCCER FIELD #2
Date Placed:
5/17/01
Time Placed:
1:45 PM
Slump (ASTM C -143):
4
Air Content:
5.0 (ASTM C -173)
Air Temperature:
85
Specimen Temperature:
91
Date Received:
5/18/01
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By:
SANDERS, JUSTIN S.
Mix Data Submitted By-
LMC
Plant Number: 3 -5.0 sk
Delivery Ticket No.: 3126015
Made By: ALPHA
Cured Specification: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure
No.: Type:
Cap
S
Date
Tested:
Age
(Days):
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Area:
S . in.
Max
Load:
PSI:
268 LAB
C -1231
5/24/01
7
12
N/A
6
28.27
84134
2970
269 LAB
C- 1231
6/14/01
28
12
WA
6
28.27
104904
3710
270 LAB
C- 1231
6/14/01
28
12
N/A
6
28.27
100843
3560
Sp eeiflcations
Results to Date.
28
3000
PASS
Notes:
Respectfully Submitted
of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Uknt (and their dedMated receplents on file in our office) and shall not be reproduced and /or dfstributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or
observed, and are not Indicative of the qualities of apparently Identical or similar specimens.
Geotechnical Engineering • Construetion`Mifeilale Taatlng • EnvGonmentai'Engineering' Constrlttn � ` 8238