PA9901-LR010602A ALPHA TESTING, INC.
Concrete Compression Test
2209 Wisconsin St., Suite e 1 100
Dallas, Texas 75229 Report
(972) 620 -8911
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
our Report No.: 00931 -105
Issue Date: 06/02/2001
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
FIELD DATA
Placement Location: BLEACHER PAD; 100'W & 150'S FROM THE SW GOAL OF SOCCER FIELD #2
Date Placed:
5/17/01
Time Placed:
1:45 PM
Slump (ASTM C -143):
4
Air Content:
5.0 (ASTM C -173)
Air Temperature:
85
Specimen Temperature:
91
Date Received:
5/18/01
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By:
SANDERS, JUSTIN S.
Mix Data Submitted By:
LMC
Plant Number: 3 -5.0 sk
Delivery Ticket No.: 3126015
Made By: ALPHA
Cured Specification: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure
No.: Type:
Cap
Sec:
Date
Tested:
Age
(Days):
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Area:
Sq. In,
Max
Load:
PSI:
268 LAB
C -1231
5/24/01
7
12
N/A
6
28.27
84134
2970
269 LAB
6114/01
28
12
N/A
6
28.27
0
270 LAB
6/14/01
28
12
N/A
6
28.27
0
Specifications:
Results to Date:
28
_
30001
WA
Notes:
Respectfully Submitted By:
of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client (and their designated recepieno on file in our office) and shall not be reproduced and /or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or
observed, and are not Indicative of the qualities of apparently Identical or similar specimens.
Geotechnical Engineering' Construction Materials Testing' Environmental Engineering `Consulting 8238
A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 10 Concrete Compression Test
Dallas, Texas 75229 Report
(972) 620 -8911
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
Our Report No.: 00931 -101
Issue Date: 06/02/2001
FIELD DATA
Placement Location: SIDEWALK, 30 - E 8 10 - N FROM THE SW CORNER OF THE PROPERTY
Date Placed:
Time Placed:
Slump (ASTM C -143):
Air Content:
Air Temperature:
Specimen Temperature:
Date Received:
Delivery Method:
Field Data Submitted By:
Mix Data Submitted By:
4/25/01
9:15 AM
4
5 (ASTM C -173)
68
70
4/26/01
PICKED UP BY ALPHA
TERVEEN, JUSTIN
LMC
Plant Number:
7 -5 SK
Delivery Ticket No.:
7100771
Made By:
ALPHA
Cured Specification:
ASTM C -31
CYLINDER COMPRESS /ON TEST RESUL TS
Lab Cure
No.: Type:
Cap
Spec:
Date
Tested:
Age
(Days):
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Area:
Sq. In.
Max
Load:
PSI:
260 LAB
C -1231
5/2/01
7
12
N/A
6
28.27
87446
3090
261 LAB
C -1231
5/23/01
28
12
N/A
6
28.27
105090
3710
262 LAB
C -1231
5/23/01
28
12
N/A
6
28.27
97216
3430
263 LAB
HOLD
HOLD
12
N/A
6
28.27
0
Speaficali
. Results to Date:
I
2 8
3000
-
PASS
Notes:
Respectfully Submitted
of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and /or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or
observed, and are not Indicative of the qualities of apparently identical or similar specimens.
Gegtechmcal Et gmeenng',{ str4chOn Ma #eIn Tes4ng * �nvir(ulmQnkal Enq�rlagttng' Corl�ulhn� � u ...: 77 6`