PA9901-LR010523A ALPHA TESTING INC. Concrete Compression Test
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 Report
(972) 620 -8911
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Our Report No.: 00931 -100
Issue Date: 05/2312001
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
FIELD DATA
Placement Location: PAVING; PARKING LOT, 200'S 8 50'E FROM 3RD BASE ON BASEBALL FIELD #2
Date Placed:
4/24/01
Time Placed:
1:30 PM
Slump (ASTM C -143):
5
Air Content:
4.8 (ASTM C -173)
Air Temperature:
73
Specimen Temperature:
88
Date Received:
4/25/01
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By:
SANDERS, JUSTIN S.
Mix Data Submitted By:
LMC
Plant Number:
7 -5.0 SK
Delivery Ticket No.:
7100732
Made By:
ALPHA
Cured Specification:
ASTM C -31
Notes:
Respectfully Submitted By:
_ of Alpha Testing, Inc.
����LL
Our test result and reports are for the exclusive use of the Client and their designated recepients on file in our office) and shall not be reproduced and/or dlsWbuted except
with express approval of ALPHA. The use of our name and test result must receive our written approval. Test result and reports apply only to the samples tested and /or
observed, and are not Indicative of the qualities of apparently identical or similar specimens. 7543
Geotechnical Engineering' Construction Materials Testing' Environmental Engineering' Consulting,.
CYLINDER COMPRESSION TEST RESULTS
Lab
Cure
Cap
Date
Age
Avg.
Avg.
Avg Depth/
Area:
Max
Load:
PSI:
No.:
Type:
Spec:
Tested:
(Days):
Length
Width
Diameter
S .In.
LAB
C -617
5/1/01
7
12
N/A
6.01
28.36
64294
2260
257
28
12
N/A
6
28.27
139417
4930
258
LAB
C -1231
5/22/01
5/22/01
28
12
N/A
6
28.27
141233
4990
259
LAB
C -1231
-.
-. -
30 08
Specifications:
28
_
- -
-— -
--
—
PASS
Results to Date:
Notes:
Respectfully Submitted By:
_ of Alpha Testing, Inc.
����LL
Our test result and reports are for the exclusive use of the Client and their designated recepients on file in our office) and shall not be reproduced and/or dlsWbuted except
with express approval of ALPHA. The use of our name and test result must receive our written approval. Test result and reports apply only to the samples tested and /or
observed, and are not Indicative of the qualities of apparently identical or similar specimens. 7543
Geotechnical Engineering' Construction Materials Testing' Environmental Engineering' Consulting,.