PA9901-LR010503A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620 -8911
Concrete Compression Test
Report
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
Our Report No.: 00931 -78
Issue Date: 05/03/2001
FIELD DATA
Placement Location: INLET BOTTOMS: 3 TOTAL ON PROJECT
Date Placed:
3/30/01
Time Placed:
11:10 AM
Slump (ASTM C•143):
3
Air Content:
5.5 (ASTM C -173)
Air Temperature:
75
Specimen Temperature:
70
Date Received:
3/31/01
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By:
HENSHAW, EKENG A
Mix Data Submitted By:
LMC
Plant Number: 3 -5 SK
Delivery Ticket No.: 3122469
Made By: ALPHA
Cured Specification: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure
No.: Type:
Cap
Spec:
Date
Tested:
Age
(Days):
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Area:
Sq. In.
Max
Load:
PSI:
201 LAB
C -617
4/6/01
7
12
N/A
6
28.27
110267
3900
202 LAB
C -617
4/27/01
28
12
N/A
6.01
28.36
124310
4380
203 LAB
C -617
4/27101
28
12
N/A
6.01
28.36
127224
4480
Specifications:
Results to Date:
28
3000
PASS
Notes:
Respectfully Submitted
of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client (ar(d their designated recepieno on Ole in our office) and shall not be reproduced and /or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or
observed, and are not indicative of the qualities of apparently identical or similar specimens.
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consti firl `;`: 6872!