PA9901-LR0104061 1 ALPHA TESTING, INC.
REPORT OF FIELD
COMPACTION TESTS
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620 -6911 - 9721263 -4937 (Metro)
FAX: 9721406 -8023
TESTED FOR DEAN CONSTRUCTION
CEDAR HILL, TEXAS
DATE 04/06/01
PROJECT WAGON WHEEL PHASE II
COPPELL, TEXAS
TEST DATA:
OUR REPORT NO. 00931 -81
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MaMRE
%
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MaSTURE
%
IN PLACE
DRY DENS"
PCF
PERCENT
COMPACTION
COMMENT*
72
04/06/01
FG
4
11.0
121
13.5
115
95
1 -A
73
04/06/01
FIG
4
11.0
121
15.0
114
94
1 -A
TEST
72 110' SOUTH AND 15' EAST FROM NORTHWEST CORNER OF
AND 20' WEST FROM NORTHEAST CORNER OF RESTROOM PAD
CC: CLINT WOLFORD, SCHRICKEL, ROLLINS, & ASSOC. - LARRY DAVIS, CITY OF
LEE STONE, CITY OF COPPELL - BRAD REID, CITY OF COPPELL
1. FILL • A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFIC
2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3, LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
0. CEMENTTREATED D. RETEST
Our het rewtb & -ports am for the eadId,w use of the Chant (and Uelr deslpnated - dpbrds on file M our office) and shall not be reprocluced at
of our name & Mst results must racers out v Most ap,.l. Test results & -pods apply only to the samples tested and /or observed, and are not
ALPHA The use
or similar speolmens.
Geotechnical Engineering Ar Construction Materials Testing 9 Environmental Engineering
A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100 Concrete Compression Test
Dallas, Texas 75229
(972) 620 -8911 Report
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Our Report No.: 00931 -79
Issue Date: 04/06/2001
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
FIELD DATA
Placement Location: PAVING, 300 - N & 30O W FROM 3RD BASE ON BASEBALL FIELD #5
Date Placed:
3/26/01
Time Placed:
10:30 AM
Slump (ASTM C -143):
5
Air Content:
5 (ASTM C -173)
Air Temperature:
51
Specimen Temperature:
60
Date Received:
3/27/01
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By:
SANDERS, JUSTIN S.
Mix Data Submitted By:
LMC
Plant Number: 7 -5.0 SK
Delivery Ticket No.: 7099389
Made By: ALPHA
Cured Specification: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure
No.: Type:
Cap
Sec:
Date
Tested:
Age
(Days):
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Area:
Sq. In.
Max
Load: PSI:
207 LAB
C -617
4/4/01
9
12
N/A
6.01
28.36
86800 3060
208 LAB
4/23/01
28
12
N/A
6
28.27
0
209 LAB
4/23/01
28
12
N/A
6
28.27
0
.Specifications:
28
- --
- annn`
Results to Date: wq
Notes:
Respectfully Submitted By:
of Alpha Testing, Inc.
Our test results and reports are for the excluslve use of the Client (and their designated recepients on file in our office) and shall not be reproduced and /or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or
observed, and are not Indicative of the qualities of apparently Identical or similar specimens.
Geotechnical Engineering' Construction Materials Testing' Environmental Engineering • Consulting 6863