PA9901-LR010308A ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 Report
(972) 620 -8911
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
Our Report No.: 00931 -49
Issue Date: 03/08/2001
FIELD DATA
Placement Location: PAVING: CENTER LANE, 200'S & 50'W FROM SOUTH CORNER OF BASEBALL FIELD #5
Date Placed:
20/01
Time Placed:
9:00 AM
Slump (ASTM C -143):
4.5
Air Content:
5.0 (ASTM C -173)
Air Temperature:
54
Specimen Temperature:
61
Date Received:
2/8/01
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By:
TERVEEN, JUSTIN
Mix Data Submitted By:
LMC
Plant Number: 7 -5.0 sk
Delivery Ticket No.: 7097924
Made By: ALPHA
Cured Specification: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure
No.: Type:
Cap
Spec:
Dale
Tested:
Age
(Days):
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Area:
Sq. In.
Max
Load:
PSI:
96 LAB
C- 617
2114/01
7
12
N/A
6
28.27
0
97 LAB
C -617
3!7101
28
12
N/A
6.02
28.46
99239
3460
98 LAB
G -617
3(7101
28
12
N/A
6.02
28.46
95201
3340
99 LAB
HOLD
HOLD
12
N/A
6
28.27
0
Specifications:
28
g3000
Notes: CYLINDERS 96 & 99 WERE DESTROYED ON SITE.
Respectfully Submitted
of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the bent (anAelr designated receplents on file In our office) and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and best results must receive our wdnen approval. Test results and reports apply only to the samples cested and/or
observed, and we not Indicative of the qualities of apparently Identical or similar specimens.
A ALPHA TESTING, INC.
Concrete Compression Test
2209 Wisconsin St., Suite e 1 100
Dallas, Texas 75229 Report
(972) 620 -8911
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
Our Report No.: 00931 -51
Issue Date: 03/08/2001
FIELD DATA
Placement Location: FOOTING, 30'N & 50'W FROM NW CORNER OF MAIN PAVILLION
Date Placed:
2/8/01
Time Placed:
8:30 AM
Slump (ASTM C -143):
4
Air Content:
WA
Air Temperature:
50
Specimen Temperature:
59
Date Received:
2/9/01
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By-
TERVEEN, JUSTIN
Mix Data Submitted By:
LATTIMORE
Plant Number: 7
Delivery Ticket No.: 7097947
Made By: ALPHA
Cured Specification: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure
No.: T
Cap
S
Date
Tested:
Age
(Days):
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Area:
Sq. In.
Max
Load:
PSI:
104 LAB
C- 617
2/15101
7
12
WA
6
28.27
99200
3500
105 LAB
C- 617
3/8/01
28
12
WA
6.01
28.36
122884
4330
106 LAB
C- 617
318101
28
12
WA
6.01
28.36
132484
4670
107 LAB
HOLD
HOLD
12
N/A
6
28.27
0
Speciticatlona.
28
3000
Results to Date:
PASS
Notes:
Respectfully Submitted
of Alpha Testing, Inc.
Our test results and reports arc for the excltsdve use of the Client (ana their designated receplena on file In our office) and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must recehre our written approval. Test mule and reports apply only to the samples tested and/or