Loading...
PA9901-LR010305A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620 -8911 Concrete Compression Test Report Tested For: DEAN CONSTRUCTION ATTN: JUNE DAVIS 701 HALL CEDAR HILL, TX 75104 Fax Number: (972) 291 -7172 Project Desc: WAGON WHEEL PH. II COPPELL, TEXAS Our Report No.: 00931 -41 Issue Date: 03/05/2001 FlELD DATA Placement Location: PAVING, 80 - S 8 50W FROM THE NE CORNER ENTRANCE TO PARKING AREA "C" Date Placed: 2/2101 Time Placed: 12:00 PM Slump (ASTM C -143): 3.5 Air Content: 5 (ASTM C -173) Air Temperature: 55 Specimen Temperature: 60 Date Received: 2/3/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: GARAY, ROBERT Mix Data Submitted By: LMC Plant Number: 7 -5.0 SK Delivery Ticket No.: 7097717 Made By: ALPHA Cured Specification: ASTM C -31 CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Cap Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 80 LAB C- 617 2/9101 7 12 N/A 6 28.27 70866 2500 81 LAB C-617 3/2/01 28 12 WA 6.02 28.46 99457 3490 82 LAB C-617 3/2101 28 12 N/A 6.02 28.46 105337 3700 83 LAB HOLD HOLD 12 N/A 6 28.27 0 Speciflcations: 28 3000 Results to Date: PASS Notes: A ALPHA TESTING INC. Concrete Compression Test 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 Report (972) 620 -8911 Tested For: DEAN CONSTRUCTION ATTN: JUNE DAVIS 701 HALL CEDAR HILL, TX 75104 Fax Number: (972) 291 -7172 Project Desc: WAGON WHEEL PH. II COPPELL, TEXAS Our Report No.: 00931 -42 Issue Date: 03/05/2001 FIELD DATA Placement Location: PAVING, SO'S 8 100'W FROM THE NE CORNER OF ENTRANCE TO PARKING LOT "C" Date Placed: 212/01 Time Placed: 1:30 PM Slump (ASTM C -143): 3.75 Air Content: 4.75 (ASTM C -173) Air Temperature: 60 Specimen Temperature: 64 Date Received: 213/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: GARAY, ROBERT Mix Data Submitted By: LMC Plant Number: 7 -5.0 SK Delivery Ticket No.: 7097725 Made By: ALPHA Cured Specification: ASTM C -31 CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Cap Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: a4 LAB C- 617 2/9/01 7 12 N/A 6 28.27 44986 1590 85 LAB C -617 312101 28 12 N/A 6.02 28.46 94480 33 `10 86 LAB C -617 3/2/01 28 12 N/A 6.02 28.46 96229 3380 87 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 _. A 3000 Results to D Notes: NOTIFIED CLIENT OF LOW 7 DAY TEST RESULT. (53% OF SPECIFIED STRENGTH) Respectfully Submitted of Alpha Testing, Inc. Our rest results and repao are for the exclusive use of r Ie alent� and their designated recepients on 6k N our o6ke) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our nave and am n suits must receive our written approval. Test resets and reports apply only to the samples tested and/or observed, and are not Indicative of the qualities of apparently Identical or shnllar specimens.