PA9901-LR010118A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620 -8911
Concrete Compression Test
Report
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
Our Report No.: 00931 -23
Issue Date: 01/18/2001
FIELD DATA
Placement Location: 15'N X 3'E FROM 2ND LIGHT POST AT SE PARKING
Date Placed:
12/21100
Time Placed:
9:40 AM
Slump (ASTM C -143):
5
Air Content:
4.5 (ASTM C -173)
Air Temperature:
37
Specimen Temperature:
48
Date Received:
12/22/00
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By:
RUNEWICZ, DANIEL
Mix Data Submitted By:
LMC
Plant Number: 7
Delivery Ticket No.: 7096534
Made By: ALPHA
Cured Specification: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab
Cure
T
Cap
S
Date
Tested:
Age
Da s :
Avg.
Lanath
Avg.
Width
Avg Depth/
Diameter
Area:
Sq. In.
Max
Load:
PSI:
32
LAB
C -1231
12/29/00
8
12
N/A
6
28.27
70804
2500
33
LAB
1/18101
28
12
WA
6
28.27
110267
3900
34
LAB
1/18/01
28
12
WA
6
28.27
109244
3860
35
LAB
HOLD
HOLD
12
WA
6
28.27
0
S
28
R esults tto Dat a:
R esults o Dat
-... _-
-
ASS
P S
Notes:
A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100 Concrete Compression Test
Dallas, Texas 75229 Report
(972) 620 -8911
Tested For: DEAN CONSTRUCTION
ATTN: JUNE DAVIS
701 HALL
CEDAR HILL, TX 75104
Fax Number: (972) 291 -7172
Our Report No.: 00931 -24
Issue Date: 01/18/2001
Project Desc: WAGON WHEEL PH. II
COPPELL, TEXAS
FIELD DATA
Placement Location: PAVING; 10'N X 40'E FROM THE RIGHT POLE AT SE PARKING
Date Placed:
12121/00
Time Placed:
11:30 AM
Slump (ASTM C -143):
5
Air Content:
5 (ASTM C -173)
Air Temperature:
40
Specimen Temperature:
52
Date Received:
12122!00
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By:
RUNEWICZ, DANIEL
Mix Data Submitted By:
LMC
Plant Number: 7
Delivery Ticket No.: 7096548
Made By: ALPHA
Cured Specification: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure
No.:
Cap
S
Data
T
Aye
Da :
Avg.
Lenoth
Avg.
Width
Avg Depth/
Diameter
Area:
Sa. In.
Max
Load:
PSI:
36 LAB
C -1231
12/29/00
8
12
WA
6
28.27
69378
2450
37 LAB
1118/01
28
12
WA
6
28.27
119846
4230
38 LAB
1/18/01
28
12
WA
6
28.27
120776
4270
39 LAB
HOLD
HOLD
12
WA
6
28.27
0
Specifications:
28
3O0
Results to Date:
PASS
Notes: