Loading...
PA9901-LR001207REPORT OF FIELD X ALPHA COMPACTION TESTS TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) _ FAX' 9727406 -8023 TESTED FOR DEAN CONSTRUCTION CEDAR HILL, TEXAS DATE 12/07/00 PROJECT WAGON WHEEL PHASE II COPPELL, TEXAS OUR REPORT NO. 00931 -8 ICJI TEST NO. v��. DATE 15 SOIL ID NUMBER OPTIMUM MOISTURE % MA%IMUM LAB DRYDENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT 14 12/07/00 tFG-6.0 2 19.5 101.5 22.6 102 100 1 -A 15 12/07/00 2 19.5 101.5 21.5 101 99 1 -A 16 12/07/00 2 19.5 101.5 21.6 101 100 1 -A 17 12/07/00 FG -0.8 2 19.5 101.5 21.5 101 100 1 -A 18 12/07/00 FG -0.8 2 19.5 101.5 23.2 100 98 1 -A 19 12/07/00 FG -0.8 2 19.5 101.5 23.5 99 98 1 -A 20 12/07/00 FG -0.8 2 19.5 101.5 23.0 100 98 1 -A I CJI 14 LVI.HItVIV. SANITARY SEWER LATTERAL LINE G -3 AT STATION #2 +00 15 SANITARY SEWER LATTERAL LINE G -3 AT STATION #4 +00 16 SANITARY SEWER LATTERAL LINE G -3 AT STATION #6 +00 17 SANITARY SEWER LINE G AT STATION #2 +10 18 SANITARY SEWER LINE G AT STATION #3 +75 19 SANITARY SEWER LINE G AT STATION #6 +00 20 SANITARY SEWER LINE G AT STATION #0 +50 CC. CLINT WOLFORD, SCHRICKEL, ROLLINS, & ASSOC. - LARRY DAVIS, CITY OF COPPELL LEE STONE, CITY OF COPPELL - BRAD REID, CITY OF COPPELL t FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENTTREATED D RETEST Geotechnical Engineering /,/ Construction Materials Testing Pi Environmental Engineering /h REPORT OF FIELD 1111 ALPHA COMPACTION TESTS TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 972/263- 4937(Metro) FAX: 9721406 -8023 TESTED FOR DEAN CONSTRUCTION CEDAR HILL, TEXAS DATE 12/07/00 PROJECT WAGON WHEEL PHASE II COPPELL, TEXAS TEST DATA: OUR REPORT NO. 00931 -9 TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 21 12/07/00 FIG 2 19.5 101.5 23.0 100 99 1 -A 22 12/07/00 FIG 2 19.5 101.5 23.2 1 100 98 1 -A 23 12/07/00 FIG 2 19.5 101.5 22.9 100 98 1 -A 24 12/07/00 FG -2.2 2 19.5 101.5 22.8 101 99 1 -A 25 12/07/00 FG -2.2 2 19.5 101.5 23.4 99 98 1 -A 26 12/07/00 FG -2.2 2 19.5 101.5 21.5 101 100 1 -A 27 12/07/00 FG -2.2 2 19.5 101.5 21.6 101 99 1 -A ax3rr•Ta�v�ra.e 21 SANITARY SEWER LINE G -1 AT STATION #2 +00 22 SANITARY SEWER LINE G -1 AT STATION #4 +00 23 SANITARY SEWER LINE G -1 AT STATION #5 +50 24 PAVING AREA - 25' SOUTH AND 25' EAST OF THE NORTHWEST CORNER 25 PAVING AREA - 60' EAST AND 25' SOUTH OF THE NORTHWEST CORNER 26 PAVING AREA - 30' NORTH AND 30' WEST OF THE SOUTHEAST CORNER 27 PAVING AREA - 20' NORTH AND 20' EAST OF THE SOUTHWEST CORNER CC: CLINT WOLFORD, SCHRICKEL, ROLLINS, & ASSOC. - LARRY DAVIS, CITY OF C^DDPI I LEE STONE, CITY OF COPPELL - BRAD REID, CITY OF COPPELL 1. FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURALSUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST Geotechnical Engineering N Construction Materials Testing N Environmental Engineering