Freeport NIP(7.0)-LR030905RoneEngineers
A. LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
CYLINDER
MARKED
SET NO.
1 1
1 2
1 3
1 4
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter Concrete
On site
SPECIFICATION REQUIREMENTS
STRENGTH: 3000 psi 28 Days
SLUMP (in):
AIR
3" 5 11
TEST METHOD: ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
5.0
5.0
5.0
5.0
Technician: Jason Astiz
Report Distribution:
(1) Duke Realty Services, LP
(I) Duke Realty Services, 12
(1) City of Coppell Engineering Dept.
(1) Potter Concrete
3% 5% AIR CONTENT 3.2 UNIT WEIGHT (pcf): NA
Concrete Compressive Cylinder 6" x l2" (area 28.27 sq. in.)
DATE
TESTED
09/04/2003
09/25/2003
09/25/2003
10/23/2003
CONCRETE COMPRESSIVE STRENGTH TEST
SAMPLE LOCATION: Same as above
REPORT (W TESTS
Started: 6:30am
PROJECT DATA
AGE
(days)
7
28
28
56
(1) Pacheco Koch Consulting Engineers
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/28/2003
WEATHER CONDITIONS: Clear, calm
TIME SAMPLED: 9:1 Sam BATCH TIME: 8:33am
TEMPERATURE (F) AIR 80 F CONCRETE: 92 F
TRUCK NO: 108 TICKET NO: 208
OVERALL PLACEMENT LOCATION:
Paving, south side, 50' north of south end, 10' west of east end
Finished: 9:45am
MAXIMUM
LOAD
(lbs. force)
105410
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(psi)
193248
037333
08/28/2003
09/05/2003
K. Scott Watson, AET
CMT Operations Manager
FRACTURE
TYPE
3730 Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 1 of 1
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
1 1
1
1
On Site
4000 psi 28 Days
5" maximum
3% 6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP DATE
(inches) TESTED
4.0 08/14/2003
4.0 09/04/2003
4.0 09/04/2003
1 4 Hold
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
SAMPLE LOCATION:
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/07/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED- 7.25am BATCH TIME: 7:O8am
TEMPERATURE (F) AIR 84 F CONCRETE: 90 F
TRUCK NO: 104 TICKET NO: 117888
AIR CONTENT 4.3 UNIT WEIGHT (pct): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line R to Z.
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
97065
131990
128490
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
10' west, 10' south of northeast
corner
COMPRESSIVE
STRENGTH
(Psi)
3430
4670
4540
4610
192290
037333
08/07/2003
09/05/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 1 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER•
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP (in): 5" maximum
AIR
TEST METHOD: ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
CYLINDER
MARKED
SET NO.
2 1
2 2
2 3
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter
On Site
3% 6% AIR CONTENT 3.7 UNIT WEIGHT (pcf): NA
MEASURED
SLUMP
(inches)
5.0
5.0
5.0
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
DATE
TESTED
08/14/2003
09/04/2003
09/04/2003
2 4 Hold
Water added at site: 5 gallons.
PROJECT DATA
SAMPLE LOCATION:
REPORT OF TESTS
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line R to Z.
AGE
(days)
7
28
28
MAXIMUM
LOAD
(Ibs. force)
94935
122430
123040
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN LD.: 7752
PLACEMENT DATE: 08/07/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED. 8 BATCH TIME: 8:14am
TEMPERATURE (F) AIR 84 F CONCRETE: 91 F
TRUCK NO: 104 TICKET NO: 1 17898
25' west, 5' north of southeast
corner
COMPRESSIVE
STRENGTH
(Psi)
3360
4330
4350
4340
192290
037333
08/07/2003
09/05/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 2 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
3
3
3
1
2
3
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter
On Site
4000 psi 28 Days
5" maximum
3% 6% AIR CONTENT 3.9 UNIT WEIGHT (pcf): NA
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
5.0
5.0
5.0
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
DATE
TESTED
08/14/2003
09/04/2003
09/04/2003
4 Hold
PROJECT DATA
REPORT OF TESTS
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line R to Z.
SAMPLE LOCATION: 150' west, 10' south of northeast
comer
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
94595
124485
125795
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/07/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED. 9-50am BATCH TIME: 9:36am
TEMPERATURE (F) AIR 86 F CONCRETE: 91 F
TRUCK NO: 104 TICKET NO: 117908
COMPRESSIVE
STRENGTH
(psi)
3350
4400
4450
4430
192290
037333
08/07/2003
09/05/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 3 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On Site
SPECIFICATION REQUIREMENTS
STRENGTII: 4000 psi 28 Days
SLUMP (in): 5" maximum
AIR %n): 3% 6%
TESTMETIIOD: ASTM C -172
CYLINDER
MARKED
SET NO.
4 1
4 2
4 3
4 4
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP DATE
(inches) TESTED
5.0 08/14/2003
5.0 09/04/2003
5.0 09/04/2003
5.0
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
SAMPLE LOCATION:
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
AGE
(days)
7
28
28
MAXIMUM
LOAD
(Ibs. force)
86170
111310
113250
Average
Does not comply with specified strength.
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/07/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED- 10:50am BATCH TIME: 10:32am
TEMPERATURE (F) AIR 86 F CONCRETE: 91 F
TRUCK NO: 1 14 TICKET NO: 1 17918
AIR CONTENT 4.8 UNIT WEIGHT (pct): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line R to Z.
175' west, 10' north of southeast
comer
COMPRESSIVE
STRENGTH
(psi)
3050
3940
4000
3970
192290
037333
08/07/2003
09/05/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
10/02/2003 56 Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 4 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER: Potter
PLANT: On Site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP (in): 5" maximum
AIR 3% 6%
TEST METHOD: ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
CYLINDER
MARKED
SET NO.
5
5
5
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
1
2
3
Duke Realty Services, LP
MEASURED
SLUMP DATE
(inches) TESTED
5.0 08/14/2003
5.0 09/04/2003
5.0 09/04/2003
5 4 Hold
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6' x 12" (area 28.27 sq. in.)
AGE
(days)
7
28
28
MAXIMUM
LOAD
(Ibs. force)
87440
111600
114740
Average
Does not comply with specified strength.
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
SAMPLE LOCATION: 100' east, 10' north of southwest
corner
COMPRESSIVE
STRENGTH
(Psi)
3090
3950
4060
4010
192290
037333
08/07/2003
09/05/2003
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/07/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED 12:10pm BATCH TIME: 1 1:49am
TEMPERATURE (F) AIR 88 F CONCRETE: 94 F
TRUCK NO: 1 TICKET NO: 1 17928
AIR CONTENT 4.7 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line R to Z.
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 5 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP(in): 5" maximum
AIR
TEST METHOD: ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
CYLINDER
MARKED
SET NO.
6 1
6 2
6 3
6 4
MEASURED
SLUMP
(inches)
5.0
5.0
5.0
Technician: Lanny Gist
Report Distribution:
(I) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Potter Concrete
Duke Realty Services, LP
Potter
On Site
DATE
TESTED
08/14/2003
09/04/2003
09/04/2003
Hold
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
REPORT OF TESTS
Started: 6:30am
PROJECT DATA
(I) Pacheco Koch Consulting Engineers
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
Report No.:
Project No.:
Date of Service:
Report Date:
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/07/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED. 1 pm BATCH TIME: 12:50pm
TEMPERATURE (F) AIR 94 F CONCRETE. 94 F
TRUCK NO: 103 TICKET NO: 117938
3% 6% AIR CONTENT 4.0 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line R to Z.
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
SAMPLE LOCATION: 20' east, 10' south of northwest
corner
AGE
(days)
7
28
28
Finished: 2:30pm
MAXIMUM
LOAD
(lbs. force)
89155
117525
118990
Average
COMPRESSIVE
STRENGTH
(Psi)
3150
4160
4210
4190
192290
037333
08/07/2003
09/05/2003
K. Scott Watson, AET
CMT Operations Manager
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 6 of 6