Freeport NIP(7.0)-LR030902RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP (in): 5" maximum
AIR 3% 6%
TEST METHOD: ASTM C -172
ASTM C -31
CYLINDER
MARKED
SET NO.
1 1
1
1
1
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP DATE
(inches) TESTED
4.0 08/29/2003
2 4.0 09/19/2003
3 4.0 09/19/2003
4 4.0 10/17/2003
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/22/2003
WEATHER CONDITIONS: clear
TIME SAMPLED: 7:30am BATCH TIME: NA
TEMPERATURE (F) AIR 80 F CONCRETE: 88 F
TRUCK NO: NA TICKET NO: 114
AIR CONTENT 3.5 UNIT WEIGHT (pet): NA
OVERALL PLACEMENT LOCATION:
East fire lane and parking area at NE corner of building
SAMPLE LOCATION: NE parking area, 20' east and 10'
north of the SW comer
AGE
(days)
7
28
28
56
MAXIMUM
LOAD
(lbs. force)
120535
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
COMPRESSIVE
STRENGTH
(Psi)
192975
037333
08/22/2003
09/02/2003
FRACTURE
TYPE
4260 Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 1 of 5
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
2 1
2 2
2 3
4000 psi 28 Days
5" maximum
3 -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
DATE
TESTED
3.5 08/29/2003
3.5 09/19/2003
3.5 09/19/2003
2 4 3.5 10/17/2003
Water added at site: 10 gallons
REPORT OF TESTS
AGE
(days)
7
28
28
56
MAXIMUM
LOAD
(lbs. force)
115480
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.:
Project No.:
Date of Service:
Report Date:
SAMPLE LOCATION: East fire lane, 125' S of the NE
comer of the building
COMPRESSIVE
STRENGTH
(Psi)
192975
037333
08/22/2003
09/02/2003
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/22/2003
WEATHER CONDITIONS: clear
TIME SAMPLED: 9:O5am BATCH TIME: 8:28am
TEMPERATURE (F) AIR 84 F CONCRETE: 89 F
TRUCK NO: 104 TICKET NO: 75
AIR CONTENT 3.2 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
East fire lane and parking area at NE corner of building
FRACTURE
TYPE
4080 Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 2 of 5
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
3 1
3 2
3 3
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter
On site
5" maximum
3 -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
DATE
TESTED
5.0 08/29/2003
5.0 09/19/2003
5.0 09/19/2003
3 4 5.0 10/17/2003
Water added at site: 10 gallons
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/22/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED: 10:4Oam BATCH TIME: 10:18am
TEMPERATURE (F) AIR 86 F CONCRETE: 90 F
TRUCK NO: 104 TICKET NO: 78
AIR CONTENT 4.2 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
East fire lane and parking area at NE comer of building
SAMPLE LOCATION: East fire lane, 30' N of NE corner
of the building
AGE
(days)
7
28
28
56
MAXIMUM
LOAD
(Ibs. force)
93515
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(Psi)
192975
037333
08/22/2003
09/02/2003
FRACTURE
TYPE
3310 Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 3 of 5
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
4000 psi 28 Days
5" maximum
3% 6% AIR CONTENT (Ye): 4.7 UNIT WEIGHT (pcf): NA
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP DATE
(inches) TESTED
4 1 4.5 08/29/2003
4 2 4.5 09/19/2003
4 3 4.5 09/19/2003
4 4 4.5 10/17/2003
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
OVERALL PLACEMENT LOCATION:
North half of south parking lot, Building column line MM to NN
SAMPLE LOCATION: 15' E and 10' S of the NW corner
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/22/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED 12: l0pm BATCH TIME: 11:47am
TEMPERATURE (F) AIR 88 F CONCRETE: 90 F
TRUCK NO: 114 TICKET NO: 86
AGE
(days)
7
28
28
56
MAXIMUM
LOAD
(Ibs. force)
87065
COMPRESSIVE
STRENGTH
(Psi)
192975
037333
08/22/2003
09/02/2003
FRACTURE
TYPE
3080 Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 4 of 5
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP (in): 5" maximum
AIR 3% 6%
TEST METHOD: ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
CYLINDER
MARKED
SET NO.
5 1 5.0 08/29/2003
5 2
5 3
MEASURED
SLUMP
(inches)
DATE
TESTED
5.0 09/19/2003
5.0 09/19/2003
5 4 5.0 10/17/2003
Technician Time: 6:30am 11:30am
12:O0pm 2:45pm
Water added at site: 10 gallons
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.:
Project No.:
Date of Service:
Report Date:
192975
037333
08/22/2003
09/02/2003
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/22/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED: 1:35prn BATCH TIME: 1.09pm
TEMPERATURE (F) AIR 92 F CONCRETE: 91 F
TRUCK NO: 104 TICKET NO: 97
AIR CONTENT 4.2 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
North half of south parking lot, Building column line MM to NN
SAMPLE LOCATION: 10' N and l0' W of the SE corner
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq in.)
and
AGE
(days)
7
28
28
56
MAXIMUM
LOAD
(lbs. force)
81250
COMPRESSIVE
STRENGTH
(psi)
FRACTURE
TYPE
2870 Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 5 of 5
Technician: Lanny Gist
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Potter Concrete
Started:
(1) Pacheco Koch Consulting Engineers
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
Finished:
K. Scott Watson, AET
CMT Operations Manager
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Reinforcing Steel Inspection
Technician Time: 9:45am 10:45am
Page 1 of 2
Technician: Jason Astiz
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Pacheco Koch Consulting Engineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
REPORT OF REINFORCING STEEL INSPECTION
Report of Inspection
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
Report No.:
Project No.:
Date of Service:
Report Date:
On this date, a Rone Engineers, Ltd. representative(s) arrived on site as
scheduled to perform Reinforcing Steel Inspection. The results are attached.
193247
037333
08/28/2003
09/02/2003
4W
K. Cott Watson, AET
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
99DD Pagel of 1
Items Suspected:
Conforming
Non
Conforming
Items Inspected:
Conforming
Non
Conforming
Items Inspected:
Conforming
Non
Conforming
Placing Drawings
Approved
y
Bar Length
and Shape
V
Column Ties Properly
Tied and Spaced
N4F
Bar Size
1/
Proper Bar Placement
Stirrup Spacing and Type
Bar Grade
I/
Properly Tied
Lapped Splices
Ban Clean
1/
Dowel Ban in Place
Welded Splices
N//f
Form Clean
Proper Bar Supports
Mechanical Splicer
y /,4
Number of Ban
1✓
Proper Cover
f/
Rone Engineers
A LEIGH COMPANY
Client:
Project: 7 /e r ZO
Discrepancies Comments:
Page 2- of
Locations and Items Inspected: cos /2 f @4_Sf
S -4/w- L A
�1 7p/ /,✓_.may /.;c_ 1 ,�!'I.Nr .7' G /Csr
�.tGr7Y cr- ha Intio °r /J /17.- TY /A- '.S/' /r /-e ..-r, l7 H/C /C /LSO/,'/ eel
Inspector's Signature: ej l 1
Report of
Reinforcing Steel Inspection
Report No.:
Project No.:
Date of Service: cf
8908 Ambassador Row
Dallas, Texas 75247
(214) 630-9745
Time: 9: Y S to JO, VS
Client/Contractor Signature: Client/Contractor Copied with Results: Yes /No
LIMITATIONS: The anat. prasmmd herein were prepered based upon to walk samples provided for rasing. We assume no responsibility for nation in quality (companion.
savanna perfonnas -a ea.) or my other fetus of dnular subject setter provided by persona or conditions over which we lava no control. Our Inters and reports are for the exclusive
use of the dints to whom they we addressed and all not be reproduced except in fbll without the w approved ofRona Engineer. Inc.
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
1 1
1 2
1 3
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter
On site
4000 psi 28 Days
5
3% 6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP DATE
(inches) TESTED
4.00 08/08/2003
4.00 08/29/2003
4.00 08/29/2003
1 4 Hold
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/01/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED: 7:2Oam BATCH TIME: 7:06am
TEMPERATURE (F) AIR 80 F CONCRETE: 86 F
TRUCK NO: 108 TICKET NO: 117778
AIR CONTENT 3.6 UNIT WEIGHT (pcf: NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line Z to GG
SAMPLE LOCATION: 10' south, 10' west of
northeast comer
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
91830
114520
113235
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
COMPRESSIVE
STRENGTH
(psi)
3250
4050
4000
4030
192011
037333
08/01/2003
09/02/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rorie Engineers, Ltd.
01 Page 1 of 7
RoneEngineers
i
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER-
PLANT:
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for cm and testing in accordance with applicable standards.
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
2 1
2 2
2 3
Duke Realty Services, LP
Potter
On site
4000 psi 28 Days
5
3 -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
4.50
4.50
4.50
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
DATE
TESTED
08/08/2003
08/29/2003
08/29/2003
2 4 Hold
REPORT OF TESTS
SAMPLE LOCATION: 40' west, 15' north of
southeast corner
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
92250
118540
114570
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.:
Project No.:
Date of Service:
Report Date:
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/01/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED: 8:2Oam BATCH TIME: 8:03am
TEMPERATURE (F) AIR 81 F CONCRETE: 86 F
TRUCK NO: 1 13 TICKET NO: 117786
AIR CONTENT 4.0 UNIT WEIGHT (pct): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line Z to GG
COMPRESSIVE
STRENGTH
(psi)
3260
4190
4050
4120
192011
037333
08/01/2003
09/02/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 2 of 7
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
3 1
3 2
3 3
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter
On site
4000 psi 28 Days
5
3 -6 %a
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
MEASURED
SLUMP DATE
(inches) TESTED
4.50 08/08/2003
4.50 08/29/2003
4.50 08/29/2003
3 4 4.50 09/26/2003
REPORT OF TESTS
SAMPLE LOCATION: 75' west, 15' north of
southeast corner
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
93200
114305
109060
Average
Does not comply with specified strength.
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(P)
3300
192011
037333
08/01/2003
09/02/2003
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/01/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED: 9:25am BATCH TIME: 9: I2am
TEMPERATURE (F) AIR 85 F CONCRETE: 87 F
TRUCK NO: 119 TICKET NO: 117796
AIR CONTENT (96): 3.9 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line Z to GG
4040
3860
3950
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
56 Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 3 of 7
RoneEngineers
to
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
4 1
4 2
4 3
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
Duke Realty Services, LP
4000 psi 28 Days
5
3 -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP DATE
(inches) TESTED
5.00 08/08/2003
5.00 08/29/2003
5.00 08/29/2003
4 4 Hold
Water added at site: 5 gallons
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/01/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED: 10:2Oam BATCH TIME: 10:O7am
TEMPERATURE (F) AIR 86 F CONCRETE: 88 F
TRUCK NO: 113 TICKET NO: 117806
AIR CONTENT 4.5 UNIT WEIGHT (pet): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line Z to GG
SAMPLE LOCATION: 125' west, 10' south of
REPORT OF TESTS northeast comer
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
AGE
(days)
7
28
28
MAXIMUM
LOAD
(Ibs. force)
94120
115365
117855
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
COMPRESSIVE
STRENGTH
(Psi)
3330
4080
4170
4130
192011
037333
08/01/2003
09/02/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rene Engineers, Ltd.
01 Page 4 of 7
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
CONCRETE COMPRESSIVE STRENGTH TEST
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER- Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
4000 psi 28 Days
5
3 -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
DATE
TESTED
5 1 5.00 08/08/2003
5 2 5.00 08/29/2003
5 3 5.00 08/29/2003
5 4 Hold
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
MIX DESIGN LD.: 7752
PLACEMENT DATE: 08/01/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED: 11: BATCH TIME: 11:OOam
TEMPERATURE (F) AIR 88 F CONCRETE: 90 F
TRUCK NO: 112 TICKET NO: 117817
AIR CONTENT 4.2 UNIT WEIGHT (pct): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line Z to GG
SAMPLE LOCATION: 100' east, 10' south of
northwest comer
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
90450
118400
113355
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(psi)
3200
4190
4010
4100
192011
037333
08/01/2003
09/02/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Roue Engineers, Ltd.
01 Page 5 of 7
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR 3% 6%
TEST METHOD: ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
CYLINDER
MARKED
SET NO.
6 1
6 2
6 3
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter
On site
4000 psi 28 Days
5
MEASURED
SLUMP
(inches)
5.00
5.00
5.00
DATE
TESTED
08/08/2003
08/29/2003
08/29/2003
6 4 Hold
Water added at site: 10 gallons
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/01/2003
WEATHER CONDITIONS:
TIME SAMPLED: 12: 10pIn
TEMPERATURE (F) AIR 92
TRUCK NO: 108
AIR CONTENT
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28,27 sq. in.)
AGE
(days)
7
28
28
Clear
BATCH TIME: 11:55am
F CONCRETE: 90 F
TICKET NO: 117826
4.7 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line Z to GO
SAMPLE LOCATION: 75' east, 10' north of
southwest corner
MAXIMUM
LOAD
(lbs. force)
89815
113850
113695
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(Pub
3180
4030
192011
037333
08/01/2003
09/02/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page6of7
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
7 4
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
MEASURED
SLUMP
(inches)
7 1 5.00
7 2 5.00
7 3 5.00
Technician: Lanny Gist
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Potter Concrete
4000 psi 28 Days
5
3 -6 %a
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
DATE
TESTED
08/08/2003
08/29/2003
08/29/2003
Hold
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 08/01/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED. I' 1Opm BATCH TIME: 12:46pm
TEMPERATURE (F) AIR 94 F CONCRETE: 92 F
TRUCK NO: 103 TICKET NO: 117836
AIR CONTENT 4.3 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot, building column line Z to GG
SAMPLE LOCATION: 25' east, 10' north of
southwest corner
AGE
(days)
7
28
28
Started- 6 Finished: 2:30pm
(1) Pacheco Koch Consulting Engineers
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
MAXIMUM
LOAD
(lbs. force)
88210
113275
113480
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630.9745
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(PH)
3120
4010
4010
4010
192011
037333
08/01/2003
09/02/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
K. Scott Watson, AET
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Pagel of