Loading...
Freeport NIP(7.0)-LR030917RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn. Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUI STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 Freeport 10 500 Freeport Parlcway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter Concrete On site REMENTS 4000 psi 28 Days 3" 5" 3% 5"/0 ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (Inches) TESTED 4.25 09/16/2003 4.25 10/07/2003 4.25 10/07/2003 4 4.25 11/04/2003 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST AGE (days) 7 28 28 56 Report No.: Project No.: Date of Service: Report Date: 194344 037333 09/09/2003 09/17/2003 PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/09/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 8:O5am BATCH TIME: 7:33am TEMPERATURE (F) AIR 78 F CONCRETE: 91 F TRUCK NO: 103 TICKET NO: 251 AIR CONTENT 3.1 UNIT WEIGHT (pcO: NA OVERALL PLACEMENT LOCATION: North parking lot, paving leave out, column lines U thru LL SAMPLE LOCATION: Column line JJ REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MAXIMUM COMPRESSIVE LOAD STRENGTH (Ibs. force) (psi) 97985 3470 Unbonded Cap FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 1 of 2 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter Concrete PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 1 3"-5" 3% 5% ASTM C -172 ASTM C -3I ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 2 2 5.0 2 3 5.0 2 4 5.0 Water added at site: 5 gallons Technician: Ryan Armstrong Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 5.0 09/16/2003 10/07/2003 10/07/2003 11/04/2003 SAMPLE LOCATION: Column line EE REPORT OF TESTS Started: 7:OOam AGE (days) 7 28 28 56 (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections Finished: 11:15am MAXIMUM LOAD (Ibs. force) 101565 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: 194344 037333 09/09/2003 09/17/2003 PROJECT DATA MIX DESIGN 1.D.: 7752 PLACEMENT DATE: 09/09/2003 WEATHER CONDITIONS: Clear TIME SAMPLED• 9 BATCH TIME: 9:O3am TEMPERATURE (F) AIR 81 F CONCRETE: 95 F TRUCK NO: 103 TICKET NO: 259 AIR CONTENT 2.9 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North parking lot, paving leave out, column lines U thru LL COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 3590 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 2