Loading...
Valley R Baptist 2-LR030320 (2)REPORT OF REINFORCING STEEL O lrerr Con Consulting Engineers a scientists 8901 Carpenter Frwy., Suite a100 Dallas, Texas 75247 Date of Service: 03/20/03 Report No.: 94021265.0168 Client No.: 69715 Project No.: 94021265 Client: Valley Ranch Baptist Church Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell, TX 75019 Coppell, TX Services: Observe placement of reinforcing for compliance with furnished drawings. PROJECT DATA Drawings Utilized: S2.00; S3.03/02, 03 and 10; S3.04/09; and S3.05/1, 2 and 3 Locations /Items Observed: Retaining Wall at 7.0- 8.5/M/J.5 (three sided) Test Method: Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Length and Shape X Coluon Tie Spacing 8 Type Bar Size X Proper Placement X Stirrup Spacing 8 Type X Bar Grade X Properly Tied X Continuous Bars X Reber Clean X Dowel Bars in Place X Welded Splices Form Clean X Proper Supports X Mechanical Splices Number of Bars X Proper Cover X Lapped Splices X Discrepancies /Comments: The following discrepancies were noted and not corrected at the time of this observation. 1. Stirrups along inside face between lines Q and S/6 and 5 needed #4 continuous reinforcing bars added at hook. 2. Stirrups needed to be straightened and #4 continuous reinforcing bars needed to be placed and spliced correctly. 3. Additional areas of improper reinforcing steel bar placement were being corrected. 4. At line V, the inside face needed #4 continuous reinforcing bars added between lines 5.1 and 7.8. Field Results Report To: Technician: M. Odom Report Distribution: lrerrraaeon ConsuXln9 Engineers 6b[lene.l. (1) HKS, Inc. (1) City of Coppell Bldg. Insp. (1) Rogers- O'Brien Construction Co. (1) Valley Ranch Baptist Church (1) Brockette Davis Drake _ (1) City of Coppell - Constr., Insp. Hussein ff. Abusaad, P. E. Senior Project Manager 309sks This report is exclusively for the use of the client indicated above and shall not be reproduced without written approval of HBC/Terracon.