Loading...
Valley R Baptist 2-LR030214CONCRETE COMPRESSIVE STRENGTH TEST F13C Report Number: 94021265.0101 lferracon 14, 2003 Dallas, carpenter P wy, Ste #100 Service Date: January Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: February 14, 2003 Attn: Robert Faille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 1:30pm Plant: 7 Supplier: LMC Truck No: 947 Ticket No: 7122769 Mix I.D. No.: 855 Project Number: 94021265 Sample Information Sample Time: 2:06pm Date Cast: January 14, 2003 Technician: Gerry B. Graham Weather Conditions: Fair, clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Grade beam and pier caps Sample location: Caps at F.7/6, G /4, 1-1/4.1, H/6 & U9.8 w /GB F /3 -G /3 bottom 2/3 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, 0 F Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 1 2 6.00 28.27 Date Tested 01/21/2003 01/21/2003 Test Method ASTM C -143 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 106,440 3,760 7 107,240 3,790 Average 3,780 1 3 6.00 28.27 02/11/2003 28 135,240 4,780 1 4 6.00 28.27 02/11/2003 28 140,300 4,960 Average 4,870 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Result Specification 4.50 3 -5 N/A 58 57 Page 1 of 2 0 YLN 1 P 01- `" "" CONCRETE COMPRESSIVE STRENGTH TEST Client: Valley Ranch Baptist Church lrerr acon Project Number:94021265 Report Number: 94021265.0101 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( sq. inches Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 03/11/2003 56 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Gerry B. Graham Report Distribution: HB /Terracon (1) HKS Inc (1) City of Coppell - Conan Insp (1) Rogers- O'Brien Construction Co. (1) Valley Ranch Baptist Church Reviewed by: (1) Brockeae Davis Drake (1) City of Coppell - Bldg Insp Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 a.«w,»o,- rw,,, „,,