Valley R Baptist 2-LR030207FIELD DENSITY TESTING
Report Number: 94021265.0121
Service Date: January 28, 2003
Item con
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630 -1010
Client: Valley Ranch Baptist Church
Attn: Robert Feille
1501 East Belt Line Road
Coppell TX 75019
Report Date: February 07, 2003
Project: Valley Ranch Baptist Church
1501 East Belt Line Rd
Coppell, TX
Number: 94021265
Material Information
Material Laboratory
No. Test Method
1. 212650003 ASTM D 698
Lab Test Data
Optimum
Max. Lab
Water
Dry Unit
Content
Weight
Description and Classification M
(pct)
Med & dk brown silty clay 16.4
104.6
Field Test Data
Test
No. Test Location
Grade Beam Backfill
81 Retest of #280, dated 01 /23103
Probe
Lift/ Mat. Depth
Elevation No. (inches)
1 6
Project Requirements
Water
Content
Minimum Dry
Range
Unit Weight
( %)
I% compaction)
=/> +3 92
Water Dry Unit Dry Unit
Content Weight Weight
M (pcf) I compaction)
21.0 96.7 92
Comments:
Test results on this report meet project specification.
Services - Perform in -place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID: 1960
Field Results Reported To: Contractor /Joe Reyes
Technician: Michael W. Whyman
Report Distribution: HBacon
(1) HKS Inc (1) City of Coppell - Constr Insp
(1) Rogers- O'Brien Construction Co. (1) Valley Ranch Baptist Church Reviewed by
(1) Brockette Davis Drake
(1) City of Coppell - Bldg Insp Hussein H. Project M a P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 W.SDW�Fwm"