Valley R Baptist 2-LR030206Technician: Arthur Tinoco Report Distribution: HBC/Terracon (1) HKS Inc (1) City of Coppell - Constr Insp (1) Rogers - O'Brien Construction Co. (1) Valley Ranch Baptist Church Reviewed by (1) Brockette Davis Drake Hussein H. Abusaad, P.E. (1) City of Coppell - Bldg Insp Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. o,.«wre" I.,. . Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST lrerrrrrrrr1W Report Number: 94021265.0087 8901 Carpenter Frwy, Ste #100 Service Date: January 7, 2003 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: February 06, 2003 Project: Valley Ranch Baptist Church Attn: Robert Feille 1501 East Belt Line Rd 1501 East Belt Line Road Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 1:40pm Date Cast: January 7, 2003 Technician: Arthur Tinoco Batch Time: 12:42pm Plant: 3 Weather Conditions: Clear, sunny Supplier: LMC Accumulative Yards: 50 Truck No: 975 Ticket No: 3154400 Placement Method: Direct Discharge Mix I.D. No.: 855 Sample Locations: Beam 3 to beam 4 bottom half Placement Location: Paving grade beam from beam 1 through 6 & half of beam 24 Field Test Data Test Result Specification Test Method Slump, inches: 5.50 3 -5 ASTM C -143 Air Content, %: 1.3 N/A ASTM C -231 Concrete Temperature,O F: 65 ASTM C1064 Ambient Temperature, ° F: 64 ASTM C -1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength (days) (lbs) (psi) No. ID (inches) ( sq. inches Tested 1 1 6.00 28.27 01/14/2003 7 111,150 3,930 1 2 6.00 28.27 01/14/2003 7 113,290 4,010 Average 3,970 1 3 6.00 28.27 02/04/2003 28 147,490 5,220 1 4 6.00 28.27 02/04/2003 28 143,420 5,070 Average 5,150 1 5 Hold Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Arthur Tinoco Report Distribution: HBC/Terracon (1) HKS Inc (1) City of Coppell - Constr Insp (1) Rogers - O'Brien Construction Co. (1) Valley Ranch Baptist Church Reviewed by (1) Brockette Davis Drake Hussein H. Abusaad, P.E. (1) City of Coppell - Bldg Insp Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. o,.«wre" I.,. . Page 1 of 1