Valley R Baptist 2-LR030129FIELD DENSITY TESTING
Report Number: 94021265.0108 1 rerracon
Dallas, Carpenter 247 Ste #100
Service Date: January 17, 2003
Dallas, Texas 75247
(214) 630 -1010
Client: Valley Ranch Baptist Church Report Date: January 29, 2003
Attn: Robert Feille Project: Valley Ranch Baptist Church
1501 East Belt Line Road 1501 East Belt Line Rd
Coppell TX 75019 Coppell, TX
Project Number: 94021265
Material Information
Material Laboratory
No. Test Method
1. 212650002 ASTM D 698
and Classification
Lab Test Data
Optimum Max. Lab
Water Dry Unit
Content Weight
Dk brown clay w /limestone
Field Test Data
Test
No. Test Location
19.8 104.8
Project Requirements
Grade Beam Backfill
73
Grid line C.8/11.1
74
Grid line 8.9/10.7
75
Grid line C.4/5.2
76
Grid line C.8/5.9
77
Grid line C.8/6.0
78
Grid line C.4/5.2
19.8 104.8
Project Requirements
Water
Dry Unit
Content
Minimum Dry
Range
Unit Weight
( %)
( % compaction)
-1/ +3 95
Probe
Water
Dry Unit
Dry Unit
Lift/ Mat. Depth
Content
Weight
Weight
Elevation No. (inches)
M
(pcf)
(% compaction)
Final
1
8
21.7
104.1
99
Final
1
8
20.9
105.0
100
1 st
1
8
19.4
105.7
100+
1 st
1
8
21.8
103.6
99
2nd
1
8
22.7
102.0
97
2nd
1
8
21.4
103.9
99
Comments:
Test results on this report meet project specification.
Services - Perform in -place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
GaugelD: 1614
Technician: Bryan C. Hughes
Report Distribution: HBC/Terracon
(1) HKS Inc (1) City of Coppell -Bldg Insp ��'"/
(1) Rogers - O'Brien Construction Co. (1) Valley Ranch Baptist Church Reviewed by
(1) Brookette Davis Drake Hussein H. Abusaad, P.E.
(1) City of Coppell - Constr Insp
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1