Loading...
Valley R Baptist 2-LR021230CONCRETE COMPRESSIVE STRENGTH TEST 1ferCOn Report Number: 94021265.0076 8901 Carpenter Frwy, Ste #100 Service Date: December 19, 2002 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 30, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 2:00pm Plant: 7 Supplier: LMC Truck No: 938 Ticket No: 7122367 Mix I.D. No.: 853 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, ° F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( sq.inches ) ASTM C1064 1 1 6.00 28.27 1 2 6.00 28.27 3 4 01/16/2003 28 01/16/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: HBC/Terracon (1) Rogers- O'Brien Construction Co. (1) City of Cappell - Constr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church H Sen In . Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 Sample Information Sample Time: 2:10pm Date Cast: December 19, 2002 Technician: Terry L. Smith Weather Conditions: Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Piers 283, 290 & 299 Placement Location: Piers Specification Test Method 3 -5 ASTM C -143 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/26/2002 7 88,480 3,130 12/26/2002 7 92,150 3,260 Average 3,200 Result 5.00 66 62 CONCRETE COMPRESSIVE STRENGTH TEST lrerr can Report Number: 94021265.0071 8901 Carpenter Frwy, Ste #100 Service Date: December 17, 2002 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 30, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 11:45am Plant: 7 Supplier: LMC Truck No: 822 Ticket No: 3154056 Mix I.D. No.: 853 Sample Information Sample Time: 12:05pm Date Cast: December 17, 2002 Technician: Terry L. Smith Weather Conditions: Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Piers 253 & 242 Placement Location: Piers Field Test Data Test Result Specification Slump, inches: 5.50 3 -5 Air Content, %: ID Concrete Temperature,O F: 56 Ambient Temperature, 0 F: 65 Plastic Unit Weight, pcf: 28.27 Laboratory Test Data 2 Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 1 2 6.00 28.27 1 3 1 4 Date Tested 12/24/2002 12/24/2002 Test Method ASTM C -143 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 82,030 2,900 7 84,320 2,980 Average 01/14/2003 28 01/14/2003 28 2,940 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: HBC/Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brocketle Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church Hussein H. jest aa P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. o,.uwmo,.Fmw. Ke CONCRETE COMPRESSIVE STRENGTH TEST l��rc con Report Number: 94021265.0073 8901 Carpenter Frwy, Ste #100 Service Date: December 18, 2002 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 30, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Proiect Number: 94021265 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 1:30pm Plant: 7 Supplier: LMC Truck No: 956 Ticket No: 7122311 Mix I.D. No.: 853 Sample Information Sample Time: 2:35pm Date Cast: December 18, 2002 Technician: Terry L. Smith Weather Conditions: Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Piers 303 & 321 Placement Location: Piers Field Test Data Test Result Specification Test Method Slump, inches: 5.00 3 -5 ASTM C -143 Air Content, %: Concrete Temperature,° F: 60 ASTM C1064 Ambient Temperature, 0 F: 61 ASTM C -1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Stren�th No. ID (inches) ( sq. inches Tested (days) (lbs) (psi 1 1 6.00 28.27 12/25/2002 7 95,590 3,380 1 2 6.00 28.27 12/25/2002 7 96,360 3,410 Average 3,400 1 3 01/15/2003 28 1 4 01/15/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: HBC /Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church H Seni o t M ad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. 4 onnwma, -rmr. xvy Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, 0 F: Ambient Temperature, ° F: Plastic Unit Weight, pcf: Laboratory Test Data Result 4.75 60 41 Set Specimen CONCRETE COMPRESSIVE STRENGTH TEST 1f�r No. Report Number: 94021265.0049 8901 enter F Car Service Date: November 27, 2002 Dallas, Texas 75247 1 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 30, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 11:40am Date Cast: November 27, 2002 Technician: Terry L. Smith Batch Time: 11:10am Plant: 7 Weather Conditions: Cloudy, mild Supplier: LMC Accumulative Yards: 10 Truck No: 938 Ticket No: 7122014 Placement Method: Truck Mix I.D. No.: 853 Sample Locations: Piers M.3/8.7, P/5.8, M.9/6.3 Placement Location: Piers Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, 0 F: Ambient Temperature, ° F: Plastic Unit Weight, pcf: Laboratory Test Data Result 4.75 60 41 Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 1 2 6.00 28.27 Test Method ASTM C -143 ASTM C1064 ASTM C -1064 Average 3,640 1 3 6.00 28.27 12/25/2002 28 144,850 5,120 1 4 6.00 28.27 12/25/2002 28 138,450 4,900 A 5,010 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: HBC/Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp / (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc Hussein 14. Abusaad, P.E. (1) valley Ranch Baptist Church Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 Specification 3 -5 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/04/2002 7 107,560 3,800 12/04/2002 7 98,290 3,480 Average 3,640 1 3 6.00 28.27 12/25/2002 28 144,850 5,120 1 4 6.00 28.27 12/25/2002 28 138,450 4,900 A 5,010 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: HBC/Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp / (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc Hussein 14. Abusaad, P.E. (1) valley Ranch Baptist Church Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 Specification 3 -5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021265.0046 1rerracon Service Date: November 26, 2002 Dall Carpenter F wy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 30, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 2:35pm Date Cast: November 26, 2002 Concrete Temperature,O F: Technician: Terry L. Smith Batch Time: 1:51 pm Plant: 7 Weather Conditions: Supplier: LMC Accumulative Yards: 10 Truck No: 956 Ticket No: 7121997 Placement Method: Truck Mix I.D. No.: 853 Sample Locations: Piers M.3/4.2 & M.3/6.1 Plastic Unit Weight, pcf: Placement Location: Piers Field Test Data Test Result Specification Test Method Slump, inches: 5.00 3 -5 ASTM C -143 Air Content, %: Concrete Temperature,O F: 60 ASTM C1064 Ambient Temperature, 0 F: 45 ASTM C -1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) ( sq. inches Tested (days) (Ibs) (psi) 1 1 6.00 28.27 12/03/2002 7 98,490 3,480 1 2 6.00 28.27 12/03/2002 7 99,550 3,520 Average 3,500 1 3 6.00 28.27 12/24/2002 28 137,460 4,860 1 4 6.00 28.27 12/24/2002 28 134,450 4,750 A verage 4, 810 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: HBC/Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST IDIC Report Number: 94021265.0044 lferracon Service Date: November 25, 2002 Dall Carpenter F wy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 30, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Proiect Number: 94021265 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 1:00pm Plant: 7 Supplier: LMC Truck No: 947 Ticket No: 7121973 Mix I.D. No.: 853 Sample Information Sample Time: 1:20pm Date Cast: November 25, 2002 Technician: Terry L. Smith Weather Conditions: Clear, mild Accumulative Yards: 10 Placement Method: Truck Sample Locations: Piers N/9.9, J.9/8.4 Placement Location: Piers Field Test Data Test Result Specification Slump, inches: 5.00 3 -5 Air Content, %: Concrete Temperature, F: 65 Ambient Temperature, ° F: 48 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area Date No. ID (inches) ( sq. inches Tested 1 1 6.00 28.27 12/02/2002 1 2 6.00 28.27 12/02/2002 Test Method ASTM C -143 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 88,460 3,130 7 96,000 3,390 Average 3,260 1 3 6.00 28.27 12/23/2002 28 130,510 4,620 1 4 6.00 28.27 12/23/2002 28 132,140 4,670 Average 4,650 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: HB.C/Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o,- uwm', .�., CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021265.0047 Service Date: November 26, 2002 1ref�0�1 Dallas, Carpenter 247 Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 30, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Laboratory Test Data Project Number: 94021265 Material Information Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 8:50am Date Cast: November 26, 2002 1 Technician: Marvin R. Arandia Batch Time: 8:07am Plant: 7 Weather Conditions: Cloudy Supplier: -MC Accumulative Yards: 20 Truck No: 1042 Ticket No: 7121975 Placement Method: Direct Discharge Mix I.D. No.: 866 Sample Locations: See placement location Placement Location: Pavement- See attached sketch Field Test Data Test Result Specification Test Method 3 -5 4.5 -7.5 Slump, inches: 5.50 Air Content, %: 2.5 Concrete Temperature,° F: 57 Ambient Temperature, 0 F: 42 Plastic Unit Weight, pcf: 1 Laboratory Test Data 28.27 Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 5 ASTM C -143 ASTM C -231 ASTM C1064 ASTM C -1064 Date Tested Age at Maximum Test Load (days) (lbs) Compressive Strength (psi) 12/03/2002 7 122,300 4,320 12/03/2002 7 121,630 4,300 Average 4,310 12/24/2002 28 161,690 5,720 12/24/2002 28 156,600 5,540 Average 5,630 01/21/2003 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 CONCRETE COMPRESSIVE STRENGTH TEST l�er con Report Number: 94021265.0047 Dallas, Carpenter F wy, Ste #100 Service Date: November 26, 2002 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 30, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 10:17am Plant: 7 Supplier: LMC Truck No: 959 Ticket No: 7121986 Mix I.D. No.: 866 Field Test Data Test Result Slump, inches: 6.00 Air Content, %: 4.0 Concrete Temperature,o F: 60 Ambient Temperature, 0 F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( sq. inches 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 2 5 5,320 Sample Information Sample Time: 11:30am Date Cast: November 26, 2002 Technician: Marvin R. Arandia Weather Conditions: Partly cloudy Accumulative Yards: 110 Placement Method: Direct Discharge Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method 3 -5 ASTM C -143 4.5 -7.5 ASTM C -231 ASTM C1064 ASTM C -1064 01/21/2003 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin R. Arandia Report Distribution: HBC/Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Conslr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc Husse (1) Valley Ranch Baptist Church Sen r H. Abtlsaa P.E. Project Ma The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/03/2002 7 111,590 3,950 12/03/2002 7 121,990 4,310 Average 4,130 12/24/2002 28 148,860 5,260 12/24/2002 28 151,780 5,370 Average 5,320 01/21/2003 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin R. Arandia Report Distribution: HBC/Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Conslr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc Husse (1) Valley Ranch Baptist Church Sen r H. Abtlsaa P.E. Project Ma The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 1 rerr con PROJECT: Vy�Fy R6wrN Page of JOB NO. 49e7 i7&s.00u7 Date ` Comp. By z� CHECKED BY: IN -PLACE DENSITY TESTS fBC eNGINEFRM, wc. .... a divisim of Terracon 8901 Cep WFrwy..Sui¢ 100 DWIft Taw ]3241 Client: Date: / 2 //p o z Project No.: Project: �r, l �a �q ��,a .te Z 7 e. .r Report No.: Moisture/Density Relationship: Standard / Modified Select Fill General Fill ✓ Material Description 1. Optimum Moisture Density Project Requirements % (PCF) Moisture Density /�.7 /a/ S — 1 +3 Q5+ 3. 4. FIELD DENSITY TESTS Test r Probe Litt/ M/D Moisture Dry Density Density No. Test Loc ation Depth Elev. No. ( °la) (pct %max 7Ns r2n n. N/ c i ,�.. .. Z..� S ?- IS ✓ r 1 t4. - 7 ✓,,:, `I�sx`lo J I Complies except where noted ( "). Standard Count: Moist Density: Gauge No.: I - Technician: Start: Stop: Contractor Notified of Results: Yes / No Narne of Person: - 404 This report Is exclusively for the use of the client indicated above and shall not be reproduced In full without written approval of HBC Engineering. Inc.