Valley R Baptist 2-LR021216CONCRETE COMPRESSIVE STRENGTH TEST 1rerrrr - r Con Report Number: 94021265.0061 8901 Carpenter Frwy, Ste #100 Service Date: December 7, 2002 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 16, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:54am Plant: 7 Supplier: LMC Truck No: 1125 Ticket No: 7122116 Mix I.D. No.: 866 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, ° F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.25 2.7 54 37 Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 1 2 6.00 28.27 3 4 Test Method ASTM C -143 ASTM C -231 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/14/2002 7 129,780 4,590 12/14/2002 7 124,760 4,410 Average 4,500 01/04/2003 28 01/04/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Sample Information Sample Time: 7:35am Date Cast: December 7, 2002 Technician: Eddie A. Elrod Weather Conditions: Cloudy Accumulative Yards: 40 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Paving- See attached sketch Specification 3 -5 4.5 -7.5 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. o ,_ LLwRo ,,,,— Page 1 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021265.0061 Service Date: December 7, 2002 Specification Test Method 3 -5 ASTM C -143 4.5 -7.5 ASTM C -231 Client: Valley Ranch Baptist Church Report Date: December 16, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Ambient Temperature, 0 F: Project Number: 94021265 Material Information Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 8:40am Date Cast: December 7, 2002 6.00 Technician: Eddie A. Elrod Batch Time: 8:05am Plant: 7 Weather Conditions: Partly cloudy Supplier: -MC Accumulative Yards: 110 Truck No: 1090 Ticket No: 7122124 Placement Method: Direct Discharge Mix I.D. No.: 866 Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Slump, inches: 5.50 Air Content, W 5.4 Concrete Temperature,° F: 52 Ambient Temperature, 0 F: 39 Plastic Unit Weight, pcf: 28.27 Laboratory Test Data 2 Set Specimen Diameter Area No. ID (inches) ( sq. inches 2 1 6.00 28.27 2 2 6.00 28.27 2 3 2 4 lferrrrrrrrr�on 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (2 14) 630 -1010 ASTM C1064 ASTM C -1064 01/04/2003 28 01/04/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 01 _U' 01 Fes,,. Vly Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/14/2002 7 110,810 3,920 12/14/2002 7 102,020 3,610 Average 3,770 01/04/2003 28 01/04/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 01 _U' 01 Fes,,. Vly CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021265.0061 Service Date: December 7, 2002 lrerrrrrrrr�on 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: December 16, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Num ber: 94021265 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 9:47am Plant: 7 Supplier: LMC Truck No: 1042 Ticket No: 7122137 Mix I.D. No.: 866 Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 4.5 Concrete Temperature,O F: 58 Ambient Temperature, ° F: 51 Plastic Unit Weight, pcf: 28.27 Laboratory Test Data 2 Set Specimen Diameter Area No. ID (inches) ( sq. inches 3 1 6.00 28.27 3 2 6.00 28.27 3 3 3 4 01/04/2003 28 01/04/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Eddie A. Elrod Report Distribution: HBC /Terracon (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brockeae Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) valley Ranch Baptist Church Hussein H. Abtfsaa P.E. Senior Project Ma The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Sample Information Sample Time: 11:15am Date Cast: December 7, 2002 Technician: Eddie A. Elrod Weather Conditions: Partly cloudy Accumulative Yards: 220 Placement Method: Direct Discharge Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method 3 -5 ASTM C -143 4.5 -7.5 ASTM C -231 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/14/2002 7 102,910 3,640 12/14/2002 7 9 3,510 Average 3,580 Page 3 of 3 0 oM u / U 0 oo6i