Valley R Baptist 2-LR021105FIELD DENSITY TESTING "
IEC
Report Number: 94021265.0026 9
Service Date: October 31, 2002 8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630 -1010
Client: Valley Ranch Baptist Church Report Date: November 05, 2002
Attn: Robert Feille Project: Valley Ranch Baptist Church
1501 East Belt Line Road 1501 East Belt Line Rd
Coppell TX 75019 Coppell, TX
Project Number: 94021265
Material Information
Material
Nn
Laboratory
Test Method
fiWlKI-1.Y1 i
ASTM D 698
Lab Test Data
Pro Bet Requirements
Optimum
Max. Lab
Water
Dry Unit
Water
Dry Unit
Content
Minimum Dry
Content
Weight
Range
Unit Weight
Description and Classification ( %)
(pcf)
( % )
(% compaction)
Med brown clay w /sand 18.2
103.9
-1/ +3
95
Field Test Data
Probe
Water
Dry Unit
Dry Unit
Test
Lift/
Mat.
Depth
Content
Weight
Weight
No. Test Location
Elevation
No.
(inches)
( %)
(pcf)
(% compaction)
South Parking Area
52 225'W of E curb line, 100 N of S curb
Final
1
6
23.0 *
97.2
94 *
line
53 200' W of E curb line, 75' N of S curb line
Final
1
6
23.2 *
98.1
94 *
54 150' W of E curb line, 120' N of S curb
Final
1
6
25.0 *
96.2
93 *
line
55 130' W of E curb line, 100' N of S curb
Final
1
6
23.6 *
97.8
94 *
line
56 1 00' W of E curb line, 100' N of S curb
Final
1
6
23.0 *
98.2
95
line
57 125' W of E curb line, 130' N of S curb
Final
1
6
24.1 *
93.9
90 *
line
Comments:
An asterisk ( *) appears next to test results which do NOT meet the project specifications.
Services - Perform in -place density and moisture content tests to determine
degree of compaction and
material
moisture
condition.
Field Test MethodASTM D2922, ASTM D3017
Gauge ID: 31787
Field Results Reported To: Contractor
Technician: Roy T. Montgomery
Report Distribution
(1) Rogers - O'Brien Construction Co. (1) City of Coppell - Constr Insp
(1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector
(1) HKS Inc
(1) Valley Ranch Baptist Church
HBC/Tn
Reviewed by
Hussein H. Abusaad, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1