Valley R Baptist 2-LR020917CONCRETE COMPRESSIVE STRENGTH TEST
eNG1NLEWNG
Report Number: 94021265.0020 8901 Carpenter Frwy., Suite #100
Service Date: August 19 2002 Dallas, Texas 75247
(214) 630 -1010
Client: Valley Ranch Baptist Church
Report Date: September 17, 2002
Attn: Robert Feille Project: Valley Ranch Baptist Church
1501 East Belt Line Road 1501 East Belt Line Rd
Coppell TX 75019 Coppell, TX
Project Number: 94021265
Material Information Sample Information
Specified Strength: 4500 psi @ 28 Days Sample Time: 3:12pm Date Cast: August 19, 2002
Technician: Jose A. Martinez
Batch Time: 2:40pm Plant: 29 Weather Conditions: Cloudy
Supplier: Hanson Accumulative Yards: 6.50
Truck No: 1883 Ticket No: 166724 Placement Method: Direct Discharge
Mix I.D. No.: 9375 Sample Locations: Head wall SW side of project
Placement Location: Head walls SE & W of project
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.25
Air Content, %: 3.9
Concrete Temperature,° F: 98
Ambient Temperature, ° F: 98
Plastic Unit Weight, pcf:
Laboratory Test Data
Set Specimen Diameter Area
No. ID (inches) ( sq. inches
ASTM C -143
ASTM C -231
ASTM C1064
ASTM C -1064
Age at Maximum Compressive
Date Test Load Strength
Tested (days) (lbs) (psi)
1
1 6.00
28.27
08/26/2002
7 127,470
4,510
1
2 6.00
28.27
08/26/2002
7 130,240
4,610
Average
4,560
1
3 6.00
28.27
09/1612002
28 153,480
5,430
1
4 6.00
28.27
09/16/2002
28 157,410
5,570
Average
5,500
Services -
Obtain samples of fresh concrete at the
placement locations, perform required field tests and cast compressive
strength samples.
Technician: Jose A. Martinez
Report Distribution: HBC Engineering
(1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp
(1) Brockelte Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by
(1) HKS Inc Hussein H. Abusaad, P.E.
(1) Valley Ranch Baptist Church Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page i of 1