Loading...
Valley R Baptist 2-LR020913CONCRETE COMPRESSIVE STRENGTH TEST o�w,x,,,: /lr ,am, Report Number: 94021265.0018 ENGI rEEWNG Service Date: August 15, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: September 13, 2002 Attn: Robert Faille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 940212 Material Information Sample information Specified Strength: 4500 psi @ 28 Days Sample Time: 2:55pm Date Cast: August 15, 2002 Concrete Temperature,o F: Technician: Marvin R. Arandia Batch Time: 1:36pm Plant: 29 Weather Conditions: Clear Supplier: Hanson Accumulative Yards: 3.50 Truck No: 1883 Ticket No: 236882 Placement Method: Direct Discharge Mix I.D. No.: 9375 Sample Locations: SW inlet near SW of property line Plastic Unit Weight, pcf: Placement Location: Inlet- SW of jobsite Field Test Data Test Result Specification Test Method Slump, inches: 3.00 ASTM C -143 Air Content, %: Concrete Temperature,o F: 95 ASTM C1064 Ambient Temperature, ° F: 97 ASTM C -1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) ( sq. inches Tested (days) (lbs) (psi) 1 1 6.00 28.27 08/22/2002 7 121,360 4,290 1 2 6.00 28.27 08/22/2002 7 119,290 4,220 Average 4,260 1 3 6.00 28.27 09/12/2002 28 172,000 6,080 1 4 6.00 28.27 09/12/2002 28 164,650 5,820 Average 5,950 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin R. Arandia Report Distribution: HBC Engineering (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp 4§L (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of i