Valley R Baptist 2-LR020912CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021265.0016 Service Date: August 14, 2002 Tir-Y-4 ` r: "NCnCarpevc 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: September 12 002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Plastic Unit Weight, pcf: Project Number: 94021265 Material Information Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 3:45pm Date Cast:August 14, 2002 7 133,200 Technician: Burl E. Thomas Batch Time: 2:30pm Plant: 29 Weather Conditions: Rain Supplier: Hanson Accumulative Yards: 10 Truck No: 1089 Ticket No: 236787 Placement Method: Direct Discharge Mix I.D. No.: 9375 Sample Locations: Walls of W inlet Placement Location: Inlets to Grapevine Creek Field Test D ata Test Result Slump, inches: 4.00 Air Content, %: 4.6 Concrete Temperature,o F: 97 Ambient Temperature, a F: 83 Plastic Unit Weight, pcf: Laboratory Test Data 1 6.00 Specification Test Method 3 -5 ASTM C -143 4 -6 ASTM C -231 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Set Specimen Diameter Area Date Tested Test Load (days) (Ibs) Strength (psi) No. ID (inches) ( sq. inches 1 1 6.00 28.27 08/21/2002 7 133,200 4,710 1 2 6.00 28.27 08/21/2002 7 133,070 4,710 Average 4,710 1 3 6.00 28.27 09/11/2002 28 151,570 5,360 1 4 6.00 28.27 09/11/2002 28 158,840 5,620 Average 5,490 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Burl E. Thomas Report Distribution: HBCeering (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc Hussein H. Abusaad, P.E. (1) Valley Ranch Baptist Church Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ,'L..,.r —kw Page 1 of 1 o CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021265.0010 Service Date: August 13, 2002 8901 Carpenter 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: September 12, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 4:15am Date Cast: August 13, 2002 7 113,880 Technician: Marvin R. Arandia Batch Time: 3:13am Plant: 3 Weather Conditions: Clear Supplier: LMC Accumulative Yards: 70 Truck No: 1049 Ticket No: 3149346 Placement Method: Direct Discharge Mix I.D. No.: 840 Sample Locations: See placement location Placement Location: Pavement Average (See attached sketch) Field Test Data Test Result Specification Test Method Slump, inches: 5.00 Air Content, %: 5.0 Concrete Temperature, F: 88 Ambient Temperature, ° F: 80 Plastic Unit Weight, pcf: Laboratory Test Data ASTM C -143 ASTM C -231 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Set Specimen Diameter Area Date Tested Test Load (days) (lbs) Strength (psi) No. ID (inches) ( sq. inches 1 1 6.00 28.27 08/20/2002 7 113,880 4,030 1 2 6.00 28.27 08/20/2002 7 109,210 3,860 Average 3,950 1 3 6.00 28.27 09/10/2002 28 139,350 4,930 1 4 6.00 28.27 09/10/2002 28 139,140 4,920 Average 4,930 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST " Report Number: 94021265.0010 ENGIMEOUPC 8901 Carpenter Frwy., Suite #100 Service Date: August 13, 2002 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: September 12, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Proiect Number: 94021265 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 4:05am Plant: 3 Supplier: LMC Truck No: 830 Ticket No: 3149355 Mix I.D. No.: 840 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 5.7 Concrete Temperature, ° F: 88 Ambient Temperature, ° F: 79 Plastic Unit Weight, pcf: 28.27 Laboratory Test Data 2 Set Specimen Diameter Area No. ID (inches) ( sq. inches 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 Sample Information Sample Time: 4:50am Date Cast: August 13, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 160 Placement Method: Direct Discharge Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method ASTM C -143 ASTM C -231 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Date Tested Test (days) Load (lbs) Strength (psi) 08/20/2002 7 101,520 3,590, 08/20/2002 7 97,450 3,450 Average 3,520 09/10/2002 28 125,700 4,450 2 4 6.00 28.27 09/10/2002 28 125,770 4,450 Average 4,450 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. o , Page 2 of 4 . "wmo ... m�x.v CONCRETE COMPRESSIVE STRENGTH TEST a Report Number: 94021265.0010 8901 carpenter c a r n peenter Frny., Suite #100 Service Date: August 13, 2002 Dallas, Texas 75247 (214) 630 -1010 Report Date: September 12, 2002 Client: Valley Ranch Baptist Church Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Proiect Number: 94021265 Material Information Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 5:40am Date Cast:August 13, 2002 Technician: Marvin R. Arandia Batch Time: 4:49am Plant: 3 Weather Conditions: Clear Supplier: LMC Accumulative Yards: 240 Truck No: 1046 Ticket No: 3149363 Placement Method: Direct Discharge Mix I.D. No.: 840 Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.00 ASTM C -143 Air Content, %: 5.5 ASTM C -231 Concrete Temperature,° F: 86 ASTM C1064 Ambient Temperature, ° F: ASTM C -1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load (days) (lbs) Strength (Psi) No. ID (inches) ( sq. inches Tested 3 1 6.00 28.27 08/20/2002 7 98,400 3,480 3 2 6.00 28.27 08/20/2002 7 102,700 3,630 Average 3,560 3 3 6.00 28.27 09/10/2002 28 123,290 4,360 3 4 6.00 28.27 09/10/2002 28 119,520 4,230 Average 4,300 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, ° F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.25 4.9 85 78 Specification Date Tested Test Method ASTM C -143 ASTM C -231 ASTM C1064 ASTM C -1064 Set Specimen CONCRETE COMPRESSIVE STRENGTH TEST o llf rram+ Report Number: 94021265.0010 un Ham: x 6901 Carpenter Frwy., Suite #100 Service Date: August 13, 2002 Dallas, Texas 75247 (214) 630 -1010 4 Report Date: September 12, 2002 Client: Valley Ranch Baptist Church Project: Valley Ranch Baptist Church Attn: Robert Feille 1501 East Belt Line Rd 1501 East Belt Line Road Coppell, TX Coppell TX 75019 Project Number: 94021265 Material Information Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 7:05am Date Cast: August 13, 2002 6.00 Technician: Marvin R. Arandia Batch Time: 6:17am Plant: 3 Weather Conditions: Clear Accumulative Yards: 320 Supplier: LMC 1106 Ticket No: 3149371 Placement Method: Direct Discharge Truck No: Sample Locations: See page 1 Mix I.D. No.: 840 Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, ° F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.25 4.9 85 78 Specification Date Tested Test Method ASTM C -143 ASTM C -231 ASTM C1064 ASTM C -1064 Set Specimen Diameter Area No. ID (inches) ( sq. inches 4 1 6.00 28.27 4 2 6.00 28.27 4 3 6.00 28.27 4 4 6.00 28.27 08/20/2002 08/20/2002 09/10/2002 09/10/2002 * Does not comply with specified strength. Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 94,370 3,340 7 93,560 3,310 Average 3,330 28 108,870 3,850" 28 113,640 4,020 Average 3,940 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin R. Arandia HBC Engineering Report Distribution: (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc H sein H. Abusaad, P.E. (1) Valley Ranch Baptist Church Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4 1 rerracon PROJECT: V�� cV ?nN 3AP11cTC r lreeiH Page of JOB NO. ° 402-13c<()QO Date '6112 Comp. By CHECKED BY: li .3 .z 'S POUR ?AVEMEMT V X OV L S r Z m Form 112 -5 -93