Valley R Baptist 2-LR020905CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021265.0024
Service Date: August 28, 2002
rx,1 vL w c;
Dallas, Carpenter Frwy., Suite #100
Dallas, Tezas 75247
(214) 630 -1010
Client: Valley Ranch Baptist Church
Report Date: September 05, 2002
Attn: Robert Feille
Project: Valley Ranch Baptist Church
1501 East Belt Line Road
1501 East Belt Line Rd
Coppell TX 75019
Coppell, TX
6.00
Project Nu mber: 94021265
Material Information
Sample Information
Specified Strength: 4500 psi @ 28 Days
Sample Time: 12:35pm Date Cast: August 28, 2002
1
Technician: Arthur . Tinoco
Batch Time: 12:00pm Plant: 29
Weather Conditions: Partly cloudy
Supplier: Hanson
Accumulative Yards: 20
Truck No: 80 Ticket No: 167014
Placement Method: Direct Discharge
Mix I.D. No.: 9375
Sample Locations: 35'W of fire hydrant
Placement Location: Paving on NE of building
(See attached sketch)
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, 0 F:
Ambient Temperature, 0 F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result Specification
6.00 3 -5
4.6 3 -6
94
96
Set
Specimen
Diameter
Area
No.
ID
(inches)
( sq. inches
1
1
6.00
28.27
1
2
6.00
28.27
1
3
1
4
Date
Tested
09/04/2002
09/04/2002
09/25/2002
Test Method
ASTM C -143
ASTM C -231
ASTM C1064
ASTM C -1064
Age at
Maximum
Compressive
Test
Load
Strength
(days)
(lbs)
(psi)
7
103,470
3,660
7
105,950
3,750
Average
3,710
28
09/25/2002 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Arthur. Tinoco
Report Distribution: HBC Engineering
(1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp
(1) Brocketle Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by
(1) Valley Ranch Baptist Church Hu ein H. Abusaad, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.