Loading...
Valley R Baptist 2-LR020905CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021265.0024 Service Date: August 28, 2002 rx,1 vL w c; Dallas, Carpenter Frwy., Suite #100 Dallas, Tezas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: September 05, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX 6.00 Project Nu mber: 94021265 Material Information Sample Information Specified Strength: 4500 psi @ 28 Days Sample Time: 12:35pm Date Cast: August 28, 2002 1 Technician: Arthur . Tinoco Batch Time: 12:00pm Plant: 29 Weather Conditions: Partly cloudy Supplier: Hanson Accumulative Yards: 20 Truck No: 80 Ticket No: 167014 Placement Method: Direct Discharge Mix I.D. No.: 9375 Sample Locations: 35'W of fire hydrant Placement Location: Paving on NE of building (See attached sketch) Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, 0 F: Ambient Temperature, 0 F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification 6.00 3 -5 4.6 3 -6 94 96 Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 1 2 6.00 28.27 1 3 1 4 Date Tested 09/04/2002 09/04/2002 09/25/2002 Test Method ASTM C -143 ASTM C -231 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 103,470 3,660 7 105,950 3,750 Average 3,710 28 09/25/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Arthur. Tinoco Report Distribution: HBC Engineering (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brocketle Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) Valley Ranch Baptist Church Hu ein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 ° ^°rw^•° ^rte• PROJECT JOB NO. c / 0 a/ � �,^ GOL K Date / Comp. By 1 rerracon Page of CHECKED BY: s-' co � Ch + 5 � � 5 5 �➢ r (e C + C S %,n S O v g E 5 v y T rt J v � 3 O s Form 112 -5 -93