Loading...
Valley R Baptist 2-LR020826CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021265.0020 ENGINEERING August 19, 2002 Dail Carpenter F wy., Suite #100 Service Date: Au g Dallas, Texas 75247 (214) 630.1010 Client: Valley Ranch Baptist Church Report Date: August 26, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Specified Strength: 4500 psi @ 28 Days Batch Time: 2:40pm Plant: 29 Supplier: Hanson Truck No: 1883 Ticket No: 166724 Mix I.D. No.: 9375 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, 0 F: Ambient Temperature, ° F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.25 3.9 98 98 Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 1 2 6.00 28.27 3 4 09/16/2002 28 09/16/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: HBC Engineering (1) Rogers - O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brockelte Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church H Senior H. jest aa P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 Sample Information Sample Time: 3:12pm Date Cast: August 19, 2002 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 6.50 Placement Method: Direct Discharge Sample Locations: Head wall SW side of project Placement Location: Head walls SE & W of project Specification Test Method ASTM C -143 ASTM C -231 ASTM C1064 ASTM C -1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 08/26/2002 7 127,470 4,510 08/26/2002 7 130,240 4,610 Average 4,560 09/16/2002 28 09/16/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: HBC Engineering (1) Rogers - O'Brien Construction Co. (1) City of Coppell - Constr Insp (1) Brockelte Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church H Senior H. jest aa P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 Sample Information Sample Time: 3:12pm Date Cast: August 19, 2002 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 6.50 Placement Method: Direct Discharge Sample Locations: Head wall SW side of project Placement Location: Head walls SE & W of project Specification Test Method