Loading...
Valley R Baptist 2-LR020823CONCRETE COMPRESSIVE STRENGTH TEST 7f �^ Report Number: 94021265.0018 clvctt EEatNc 81 Carpenter Service Date: August 15, 2002 D llas, Texas 75247 Suite atop (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: August 23, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Sample Information Specified Strength: 4500 psi @ 28 Days Sample Time: 2:55pm Date Cast: August 15, 2002 Technician: Marvin R. Arandia Batch Time: 1:36pm Supplier: Hanson Truck No: 1883 Mix I.D. No.: 9375 Plant: 29 Weather Conditions: Clear Accumulative Yards: 3.50 Field Test Data Test Slump, inches: 3.00 ASTM C -143 Air Content, %: Concrete Temperature, F: 95 ASTM C1064 Ambient Temperature, 0 F: 97 ASTM C -1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) ( sq. inches Tested (days) (lbs) (psi) 1 1 6.00 28.27 08/22/2002 7 121,360 4,290 1 2 6.00 28.27 08/22/2002 7 119,290 4,220 Average 4,260 1 3 09/12/2002 28 1 4 09/12/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin R. Arandia Report Distribution: HBC Engineering (1) Rogers- OBrien Construction Co. (1) City of Coppell - Constr Insp (1) Brockette Davis Drake Inc (1) City of Coppell Building Inspector Reviewed by (1) HKS Inc (1) Valley Ranch Baptist Church Hussein H. Project M a P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Ticket No: 236882 Placement Method: Direct Discharge Sample Locations: SW inlet near SW of property line Placement Location: Inlet- SW of jobsite Result Specification Test Method Page 1 of 1 FIELD DENSITY TESTING r X_ ,�,w16. Report Number: 94021265.0017 LWANELalnG Service Date: August 15, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630 -1010 Client: Valley Ranch Baptist Church Report Date: August 23, 2002 Attn: Robert Feille Project: Valley Ranch Baptist Church 1501 East Belt Line Road 1501 East Belt Line Rd Coppell TX 75019 Coppell, TX Project Number: 94021265 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water 40 Water Dry Unit Content Minimum Dry Material Laboratory Content Weight Range Unit Weight No. Test Method Description and Classification M (pgf) ( %) (% compaction) 1. 212650005 ASTM D 698 Med brown clay w /sand 18.2 103.9 -1/ +3 95 Field Test Data Probe 19.6 Water Dry Unit Dry Unit Test Lift/ Mat. Depth 1 St Content Weight Weight No. Test Location Elevation No. (inches) 95 M (pcf) (% compaction) Comments: Test results on this report meet project specification. Services - Perform in -place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: Technician: Phillip R. Green Report Distribution: HBC Engineering (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp -q.,/1 6 (1) Brockette Davis Drake Inc (1) city of Coppell Building Inspector Reviewed by 4 (1) Valley n Ranch Baptist Church Hussein P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 ,,,o�. .,� w, 12" Storm Drain, Roof Drain 40 10'S and 35'W of SE corner of building 1st 1 6 20.8 98.9 95 41 10'S and 40'W of SE corner of building 2nd 1 6 19.3 99.4 96 42 10'S and 45'W of SE corner of building 3rd 1 6 19.6 100.1 96 43 10'S and 165'W of SE corner of building 1 St 1 6 20.0 98.8 95 44 10' S and 170'W of SE corner of building 2nd 1 6 20.3 99.8 96 45 10' S and 175'W of SE corner of building 3rd 1 6 19.1 102.4 99 Comments: Test results on this report meet project specification. Services - Perform in -place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: Technician: Phillip R. Green Report Distribution: HBC Engineering (1) Rogers- O'Brien Construction Co. (1) City of Coppell - Constr Insp -q.,/1 6 (1) Brockette Davis Drake Inc (1) city of Coppell Building Inspector Reviewed by 4 (1) Valley n Ranch Baptist Church Hussein P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 ,,,o�. .,� w,