Valley R Plaza 2B-LR030818CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94031170.0056
Service Date: July 18, 2003
Client: Phase II BLMA Limited
Attn: Tad Weatherford
5950 Berkshire Ln Ste 410
Dallas TX 75225
Material Information
Specified Strength: 3000 psi @ 28 Days
lferr�acon
8901 Carpenter Fnvy, Ste #100
Dallas, Texas 75247
(214) 630 -1010
Keporr uate: August its,
Project: Valley Ranch Plaza Phase II
817 South MacArthur Blvd
Coppell, TX
71
)ject Number: 94031170
Sample Information
Sample Time: 6:12am Date Cast: July 18, 2003
Technician: Joseph B. Gordon
Weather Conditions: Clear
Accumulative Yards: 70
Placement Method: Direct Discharge
Sample Locations: 45' E of NW wall & 10' S of N corner
Placement Location: Paving N of building, 50' E of NW corner &
30'N of bldg.
Batch Time: 4:53am Plant: 89
Supplier: Beall
Truck No: 123 Ticket No: 89028652
Mix I.D. No.: 1504
Water Added Onsite Before Test: 10 Gallons
Field Test Data
Test
Result
Specification
Test Method
Slump, inches:
4.75
ASTM C -143
Air Content, %:
4.3
ASTM C -231
Concrete Temperature, 0 F:
87
ASTM C -1064
Ambient Temperature, ° F:
81
ASTM C -1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter
Area
Date
Test Load
Strength
No. ID (inches)
( sq. inches
Tested
(days) (lbs)
(psi)
1 1 6.00
28.27
07/25/2003
7 98,170
3,470
1 2 6.00
28.27
07/25/2003
7 95,430
3,370
Average
3,420
1 3 6.00
28.27
08/15/2003
28 120,190
4,250
1 4 6.00
28.27
08/15/2003
28 117,840
4,170
Average
4,210
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Joseph B. Gordon
Report Distribution: r n
(1) Phase II ALMA Limited
(1) City of Coppell TX Reviewed by
(1) City of Copper TX IC lave nd, P.E.
(1) Mycon General Contractors
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 °1 `"" �.'